A person in a high-visibility jacket and hard hat looks across an industrial yard.
Set the organisational boundary before classifying the source.
Diagram text description

A person wearing a hard hat and high-visibility jacket faces industrial buildings, a vehicle yard and electricity infrastructure. The scene illustrates business activity without establishing ownership, control or any measured inventory.

Scope 1, Scope 2 and Scope 3 organise a corporate greenhouse gas inventory according to the reporting company’s relationship to the emitting activity. Scope 1 covers direct sources within the chosen organisational boundary. Scope 2 covers generation of purchased or acquired electricity, steam, heat and cooling that the company consumes. Scope 3 covers other indirect value-chain emissions.

Set the organisational boundary before classifying individual sources. The examples here use an operational-control approach. A different consolidation approach or a different control arrangement can change which operations enter the inventory and how a leased or contracted activity is treated. Write the approach beside the reporting entity, period and source list so the classification can be checked.

Direct sources, purchased energy generation and other value-chain activity pair with scopes one, two and three.
Apply the organisational boundary, then place each source in its appropriate scope.
Diagram text description

Under a declared organisational approach, Scope 1 covers direct sources inside the boundary. Scope 2 covers generation of purchased or acquired energy consumed by the company. Scope 3 covers other indirect upstream and downstream value-chain emissions. Each account needs the activity and boundary evidence for its sources.

The scopes help you choose evidence and assign responsibility. A fuel log for a controlled vehicle, an electricity bill and a supplier material estimate describe different sources and need different methods. Begin by identifying who operates or controls the emitting source, whether the company buys energy from it, and where the activity sits in the value chain. Keep unresolved boundary questions visible while collecting the evidence needed to answer them.

Scope 1: direct operational emissions

Scope 1 concerns direct emissions from sources inside the organisational boundary. In an operational-control inventory, review the equipment and operations the company controls. Common sources include combustion in boilers and generators, fuel burned in controlled vehicles, and relevant fugitive releases from refrigeration or other equipment.

Use the source list to collect the right activity records. A boiler may need fuel consumption by type and period. A fleet source needs fuel or other suitable operational records. A refrigerant source needs evidence of the gas and releases, such as service and recharge records interpreted using the appropriate method. Check for relevant process sources rather than assuming combustion and leaks are the whole inventory.

A controlled-source boundary contains boilers, generators, fleet vehicles and refrigerant releases.
Check direct combustion and fugitive sources against the chosen boundary.
Diagram text description

For the operational-control example, consider fuel combustion in controlled boilers and generators, controlled vehicles and relevant refrigerant releases. Each source still needs evidence of control and its own activity data. A contractor source needs a separate boundary and value-chain assessment.

Ownership helps identify which records to inspect but does not answer every control question. If a contractor runs equipment as part of an independently operated service, examine the contract and operational responsibilities. Establish whether the source is inside the company’s consolidation boundary before placing the emissions in Scope 1. The classification table below shows how a change in who controls transport affects the result.

Record the person responsible for each direct source and the evidence they must provide. When the fuel log or service record covers a different period, reconcile it or state the estimation method. That keeps the source’s scope separate from uncertainty in the quantity.

Scope 2: purchased electricity, heat, steam and cooling

Scope 2 accounts for emissions from generating purchased or acquired energy consumed by the reporting company. A grid electricity bill is a familiar example, but the account also covers purchased steam, heat and cooling. The emitting plant can sit outside the company’s own operations while its generation serves the company’s energy use.

Keep location-based and market-based results distinct where dual reporting applies. The location-based method uses the applicable grid-average basis. The market-based method uses qualifying supplier or contractual information under the relevant hierarchy and quality criteria. Both need a documented consumption record. They are alternative reporting methods for the same consumption and should not be added together.

Location-based uses grid-average evidence. Market-based uses qualifying contractual evidence.
Keep the two Scope 2 methods distinct when dual reporting applies.
Diagram text description

Location-based accounting uses the applicable grid-average basis for the purchased energy. Market-based accounting uses eligible contractual information under the applicable quality rules and hierarchy. Both refer to documented consumption, with separate method evidence. Do not add the two method results together.

GHG Protocol’s technical FAQ explains that an organisation operating where product- or supplier-specific information is available must report both methods. It also explains the hierarchy when particular contractual information is unavailable. A tariff name or a claim of renewable supply needs supporting evidence before it can determine the market-based factor. Retain the contract, applicable attributes, factor and period with the calculation.

Check the factor’s boundary as well. A wider life-cycle factor can include upstream activities beyond energy generation. Identify and treat those separately under the selected accounting method instead of allowing an unexplained blend of scopes. For a leased building, first establish the organisation’s control and energy arrangement, then obtain consumption or an appropriately documented estimate for its share.

Scope 3: value-chain emissions

Scope 3 extends the inventory to other indirect activities across the value chain. Upstream sources can include purchased goods, capital goods, fuel and energy supply activities, third-party transport and business travel. Downstream sources can include distribution, use of sold products and end-of-life treatment. Assess the category that fits the activity and its role in the company’s value chain.

The GHG Protocol calculation guidance organises Scope 3 methods into fifteen categories. Use that full structure as a screening register. For each category, record applicability, available activity, method, data quality and any exclusion or open evidence request. A short list of familiar sources can miss material activities or place the same activity in two categories.

Upstream purchases and freight appear before the reporting company, with distribution, product use and disposal after it.
Screen upstream and downstream categories alongside the company’s direct and purchased-energy accounts.
Diagram text description

Upstream activity can include purchased goods and relevant third-party transport. The reporting company has its direct-source and purchased-energy accounts. Downstream activity can include distribution, product use and end of life. Assess the applicable Scope 3 categories and avoid counting the same activity twice within the inventory.

Start with a documented screen when supplier-specific data is limited. A spend estimate or another proxy can help identify priorities if the method and its limitations are visible. Keep that estimate labelled so a reader can distinguish it from a result based on a specific supplier, product and period. Update the model when better evidence becomes available.

Reconcile the category boundaries before aggregation. Freight may already sit inside a supplier-provided product dataset, for example. Check where that dataset ends before adding a separate transport line. Preserve what each source includes and who owns the missing information so an improvement plan can focus on the most consequential gaps.

A classification table for common business activities

Classify the source under the same consolidation approach used for the inventory. The fictional examples below assume operational control. They show how company involvement, ownership, control, purchased energy and value-chain role lead to different evidence requests.

Activity and conditionClassification in the exampleEvidence to keep
Gas boiler operated under the company’s controlScope 1 combustionControl responsibility, fuel and period records.
Company-operated van within the boundaryScope 1 mobile combustionVehicle control and fuel or activity records.
The same freight movement bought from an independently controlled carrier outside the boundaryScope 3, relevant purchased transport categoryCarrier contract, transport role, mass, route and method.
Grid electricity bought and consumed at the controlled siteScope 2 generationConsumption, grid basis and any qualifying contractual evidence.
Refrigerant release from controlled cooling equipmentScope 1 fugitive sourceGas identity, service records and the selected estimation method.
Employee business flight purchased from an airlineScope 3 business travelBusiness purpose, itinerary and travel method.
Leased forklift with control responsibilities still unconfirmedPending boundary reviewLease, operating responsibilities and who controls the source.

Table 1, shown one row at a time. Every field is retained.

Row 1

Activity and condition
Gas boiler operated under the company’s control
Classification in the example
Scope 1 combustion
Evidence to keep
Control responsibility, fuel and period records.

Row 2

Activity and condition
Company-operated van within the boundary
Classification in the example
Scope 1 mobile combustion
Evidence to keep
Vehicle control and fuel or activity records.

Row 3

Activity and condition
The same freight movement bought from an independently controlled carrier outside the boundary
Classification in the example
Scope 3, relevant purchased transport category
Evidence to keep
Carrier contract, transport role, mass, route and method.

Row 4

Activity and condition
Grid electricity bought and consumed at the controlled site
Classification in the example
Scope 2 generation
Evidence to keep
Consumption, grid basis and any qualifying contractual evidence.

Row 5

Activity and condition
Refrigerant release from controlled cooling equipment
Classification in the example
Scope 1 fugitive source
Evidence to keep
Gas identity, service records and the selected estimation method.

Row 6

Activity and condition
Employee business flight purchased from an airline
Classification in the example
Scope 3 business travel
Evidence to keep
Business purpose, itinerary and travel method.

Row 7

Activity and condition
Leased forklift with control responsibilities still unconfirmed
Classification in the example
Pending boundary review
Evidence to keep
Lease, operating responsibilities and who controls the source.

The vehicle counterexample changes the emitting-source relationship. A van operated inside the company’s boundary has direct fuel combustion. Purchasing the same delivery service from an independent carrier outside that boundary gives the buyer an indirect transport activity. The condition is the change in control and service arrangement, not a change in the goods carried.

  1. Establish whether the emitting source sits inside the declared organisational boundary and creates direct emissions.
  2. For an indirect source, check whether it generates energy the company purchases or acquires and consumes.
  3. Assess other indirect activity in the appropriate value-chain category. If control or the contract remains unclear, resolve that question before final classification.

Apply the same tests consistently across sites and periods. Keep the supporting condition beside the assigned scope so another reviewer can follow the decision.

How to build the first inventory

Fictional first-inventory record. Alder Span Works is preparing its 2025 corporate baseline using operational control. It operates one workshop, buys grid electricity and purchases materials and freight. The record below assigns evidence owners before quantities and factors are complete. It makes no claim of an approved emissions total.

Source or boundary fieldScope and evidence ownerOpen evidence or decision
Reporting entity and approachAlder Span Works, operational control. Inventory manager owns the boundary statement.Confirm the workshop and activities included for the whole period.
Controlled workshop boilerScope 1. Facilities owns fuel records.Reconcile a missing supplier invoice with tank or meter records.
Purchased workshop electricityScope 2. Facilities owns consumption; energy buyer owns contract evidence.Confirm the applicable reporting methods and factor evidence.
Purchased metal componentsScope 3 purchased goods. Procurement owns quantities and supplier requests.Start with a documented estimate while product-specific data is requested.
Independently operated inbound freightScope 3 purchased transport. Logistics owns contracts and routes.Check whether the supplier’s material data already includes the same leg.
Leased forkliftClassification pending. Operations owns the lease enquiry.Establish operational control and avoid treating an unresolved source as zero.
Review and baseline versionInventory manager coordinates review and versions the baseline.Keep quantities, methods, limits and exclusions with the source register.

Table 2, shown one row at a time. Every field is retained.

Row 1

Source or boundary field
Reporting entity and approach
Scope and evidence owner
Alder Span Works, operational control. Inventory manager owns the boundary statement.
Open evidence or decision
Confirm the workshop and activities included for the whole period.

Row 2

Source or boundary field
Controlled workshop boiler
Scope and evidence owner
Scope 1. Facilities owns fuel records.
Open evidence or decision
Reconcile a missing supplier invoice with tank or meter records.

Row 3

Source or boundary field
Purchased workshop electricity
Scope and evidence owner
Scope 2. Facilities owns consumption; energy buyer owns contract evidence.
Open evidence or decision
Confirm the applicable reporting methods and factor evidence.

Row 4

Source or boundary field
Purchased metal components
Scope and evidence owner
Scope 3 purchased goods. Procurement owns quantities and supplier requests.
Open evidence or decision
Start with a documented estimate while product-specific data is requested.

Row 5

Source or boundary field
Independently operated inbound freight
Scope and evidence owner
Scope 3 purchased transport. Logistics owns contracts and routes.
Open evidence or decision
Check whether the supplier’s material data already includes the same leg.

Row 6

Source or boundary field
Leased forklift
Scope and evidence owner
Classification pending. Operations owns the lease enquiry.
Open evidence or decision
Establish operational control and avoid treating an unresolved source as zero.

Row 7

Source or boundary field
Review and baseline version
Scope and evidence owner
Inventory manager coordinates review and versions the baseline.
Open evidence or decision
Keep quantities, methods, limits and exclusions with the source register.
  1. Define and document the organisational and reporting boundaries.
  2. Collect activity against the source register and assign each missing record.
  3. Select applicable calculation methods and factor versions.
  4. Calculate and classify the supported lines, with units and assumptions visible.
  5. Review gaps, overlap and material uncertainty before approving totals.
  6. Issue a versioned baseline with exclusions, limitations and a plan for updates.

This is a corporate inventory record. A footprint for one component or finished product would need its own unit, processes, allocation and life-cycle boundary. Keep that product task identifiable when its evidence is reused in the corporate estimate.

Where product and supplier data becomes critical

Product and supplier data becomes usable when it matches the actual purchase or product configuration. Link the supplier source to the SKU and BOM revision, material mass, factor coverage, geography and data period. Check that the source’s unit and included processes fit the calculation before reusing the number.

For example, a purchased housing may have a revised BOM with a different metal mass. The supplier document must describe the relevant housing, site and period, and its factor must cover the material and production stages the calculation needs. A result for another revision or a wider assembly cannot be transferred without reconciliation. Record the matching decision and what remains uncertain.

A corporate purchased-goods estimate can use product-level information, but the two accounting objects need distinct records. The corporate line concerns purchases and the reporting period; the product footprint concerns a defined product unit and life-cycle scope. Reconcile quantity and coverage when moving evidence between them, and check whether transport or another process is already included.

Prioritise the suppliers and datasets that could change an important decision. Keep the proxy basis visible while better component or process evidence is requested, then record how the new data changes the estimate.

Keep value-chain evidence connected to the inventory

Keep the source register, activity evidence, method, factor version and reviewer decision connected. Give each line a stable reference and save the assumptions that affect its scope or amount. An unresolved lease question and an estimated activity quantity are different issues and should each have an owner and an evidence request.

For a supplier line, retain the product revision and the document used to support the estimate. For an energy line, retain the consumption and the evidence for each reporting method. For a direct source, retain the control decision and activity record. This lets a reviewer reconstruct the inventory and identify which updates affect a reported subtotal.

When a record changes, preserve the earlier baseline and explain the revision. A new supplier dataset can improve a quantity or factor, while a changed operating arrangement may also affect the classification. Review both before carrying a number into the next inventory. Record the date, reason, owner and approved use so the next preparer can distinguish a completed decision from a remaining assumption.

Conclusion: use scopes to assign responsibility

Use the scopes to assign evidence and action owners. They describe the relationship between the reporting company and an emitting activity. The classification provides a way to organise the inventory and the work needed to improve it.

Start with a clear organisational approach, then check direct sources, purchased energy and the full value chain. Use conditional classifications where the facts require them and keep unresolved control questions on the register. A complete-looking total should not conceal an unassessed source.

Once the baseline is traceable, prioritise material emissions alongside the company’s influence and opportunities to improve data. Give the next evidence request to a named owner, preserve the prior version when conditions change, and carry the boundary and uncertainty into any statement based on the result.