A woman reviews printed papers beside a calculator, notebook and laptop displaying charts.
Connect the inventory with the source records behind it.
Diagram text description

An illustrative analyst scene shows a woman reviewing papers at a desk beside a calculator, notebook and laptop with charts. It supplies review context, not verified company data, a measured utility result or an assurance conclusion.

Carbon accounting turns a company’s activities into a greenhouse gas inventory under a stated boundary and method. The company decides which entities and sources belong, collects activity evidence, applies suitable factors and reports compatible results in CO2e. The work is broader than multiplying an energy bill by a rate: missing sites, duplicate records or mismatched units can undermine an otherwise tidy total.

The GHG Protocol Corporate Standard provides an accounting and reporting framework for corporate inventories. A practical process connects the entity boundary, source register, original records, calculation and review. Keep unresolved inputs visible throughout that chain. An organized inventory can support scrutiny without itself being an assurance opinion.

Boundary and source identity connect to quantity, unit, period and owner, then factor and gas calculation and a reviewed gross inventory.
Keep the original source record connected to the inventory result.
Diagram text description

Define the reporting entity, facility and source boundary. Retain each original source document with quantity, unit, period and owner. Link the selected factor version and gas or CO2e calculation, then the reviewer disposition and gross inventory line. Missing sources and unresolved records remain visible instead of silently becoming zero.

This guide shows the process with fictional fuel and electricity calculations and a utility record carried into a provisional inventory line. The examples teach units and evidence handling, not a real company footprint. A corporate inventory also differs from a product footprint, which follows a particular product and its defined life-cycle boundary rather than simply reproducing the company’s annual scope totals.

Start with the organization you are measuring

Record the organization and period before asking for emissions data. Facilities, subsidiaries, leased assets and joint operations need a consistent consolidation policy. The GHG Protocol approaches distinguish equity share, financial control and operational control; they answer different questions about economic interest or control. Apply the selected approach consistently rather than choosing whichever treatment produces the lowest result for each site.

EPA’s organizational-boundary guidance explains these alternatives. Build an entity-and-asset list with the relevant relationship, inclusion decision, supporting evidence and effective date. Finance, legal and operational records can clarify a disputed arrangement. An invoice addressed to the company does not independently establish that it controls the emitting source.

Keep the reporting dates explicit. A calendar-year inventory may contain activity evidence issued later or a facility acquired partway through the year. Record which activity period belongs and assess changes under the applicable framework and recalculation policy. Do not use an invoice date as a substitute for the period of consumption.

The worked examples below assume a fictional Harbour Workshop corporate boundary using operational control. They illustrate only May 2025 activity for two sources within a calendar 2025 inventory, not a complete annual company result.

Build an emissions-source register before calculating

Build a source register before choosing calculators. It should connect a physical activity with its facility or business relationship, scope and evidence owner. EPA’s source-screening guidance separates direct sources, purchased energy and value-chain activities. That distinction helps prevent an expense label from deciding the accounting treatment.

Source relationshipInitial classificationEvidence to retain
Fuel burned in an included controlled boiler or vehicleDirect Scope 1 sourceEquipment identity, control assessment and consumption record
Electricity, heat, steam or cooling purchased for an included operationIndirect Scope 2 sourceSupply relationship, meter or activity record and applicable accounting basis
Other relevant supplier, transport, waste or business-travel activityAssess the applicable Scope 3 categoryRelationship, physical activity, method and category boundary

Table 1, shown one row at a time. Every field is retained.

Row 1

Source relationship
Fuel burned in an included controlled boiler or vehicle
Initial classification
Direct Scope 1 source
Evidence to retain
Equipment identity, control assessment and consumption record

Row 2

Source relationship
Electricity, heat, steam or cooling purchased for an included operation
Initial classification
Indirect Scope 2 source
Evidence to retain
Supply relationship, meter or activity record and applicable accounting basis

Row 3

Source relationship
Other relevant supplier, transport, waste or business-travel activity
Initial classification
Assess the applicable Scope 3 category
Evidence to retain
Relationship, physical activity, method and category boundary

Screen all relevant sources rather than importing only the largest utility accounts. Refrigeration, industrial gases, backup generation and less visible value-chain activities can require different evidence. A simplified calculator may not cover every Scope 3 category; its available input fields do not define the full inventory boundary.

Give missing sources or unresolved classifications an explicit status. A blank row can mean absent, uninvestigated or unavailable data, and those meanings should not be confused. Retain the register as the checklist against which the calculation file will later be reconciled.

Collect activity records that can be traced back

Collect records that another person can trace back. Fuel quantities, purchased electricity, travel, procurement and supplier information need a source identity, original quantity and unit, service or activity dates, facility or relationship, evidence owner and coverage. Preserve the original document alongside the value used in the calculation.

Check what the record measures. Fuel bought is not necessarily fuel consumed during the period, and a currency amount is not a physical energy quantity. A utility invoice may span months or cover several meters. A supplier value may relate to a different product, geography or life-cycle boundary. Record the interpretation before converting or allocating the number.

When evidence is missing, retain the gap and the treatment selected. A justified estimate needs its method and limitation; an unsupported row may need to remain unresolved. Do not turn missing activity into zero simply to complete the spreadsheet.

Assign responsibility for clarification. The facilities owner may explain a meter, procurement may identify a supplier dataset and finance may locate a corrected invoice. Keep the question, requested evidence and current provisional value linked. That makes the next review specific instead of leaving a future preparer to guess why the number was chosen.

Convert activity to CO2e without mismatching units

Match the factor to the activity’s source or fuel, geography, year, original unit and gas-output basis, retaining its version. The following calculation is entirely fictional. Harbour Workshop consumes an invented 400 L of teaching fuel in May 2025. Every coefficient and GWP below is invented, including hypothetical 100-year multipliers of 20 for CH4 and 100 for N2O; these are not IPCC values or recommended operational factors.

GasInvented factorActivity-to-gas calculationTeaching CO2e conversion
CO21.8 kg CO2/L400 L × 1.8 = 720 kg CO2720 × 1 = 720 kg CO2e
CH40.5 g CH4/L400 L × 0.5 = 200 g CH4 = 0.2 kg CH40.2 × 20 = 4 kg CO2e
N2O0.1 g N2O/L400 L × 0.1 = 40 g N2O = 0.04 kg N2O0.04 × 100 = 4 kg CO2e

Table 2, shown one row at a time. Every field is retained.

Row 1

Gas
CO2
Invented factor
1.8 kg CO2/L
Activity-to-gas calculation
400 L × 1.8 = 720 kg CO2
Teaching CO2e conversion
720 × 1 = 720 kg CO2e

Row 2

Gas
CH4
Invented factor
0.5 g CH4/L
Activity-to-gas calculation
400 L × 0.5 = 200 g CH4 = 0.2 kg CH4
Teaching CO2e conversion
0.2 × 20 = 4 kg CO2e

Row 3

Gas
N2O
Invented factor
0.1 g N2O/L
Activity-to-gas calculation
400 L × 0.1 = 40 g N2O = 0.04 kg N2O
Teaching CO2e conversion
0.04 × 100 = 4 kg CO2e

The fictional controlled-combustion contribution is 720 + 4 + 4 = 728 kg CO2e, or 0.728 tonnes. Gram outputs are converted to kilograms before applying the teaching GWPs. For a separate purchased-electricity record, assume 800 kWh × an invented 0.25 kg CO2e/kWh = 200 kg CO2e, or 0.200 tonnes. That is a Scope 2 contribution, not another direct fuel source. Its coefficient already returns CO2e and receives no extra GWP multiplier.

The two illustrated contributions total928 kg CO2e, or 0.928 tonnes, with scopes still shown separately. This is only a two-source teaching subtotal. The utility contribution remains provisional for the evidence question described later.

Reject a 400 kWh fuel input against a per-litre factor: the denominator does not match. Also reconcile the fuel invoice and consumption log if both describe the same 400 L; they are two pieces of evidence, not two combustion activities. For a real inventory, obtain appropriate factors and GWP references, test applicability and preserve every unit conversion rather than using the invented teaching values.

Treat purchased electricity as a specific Scope 2 calculation

Purchased electricity is an indirect Scope 2 activity associated with the energy consumed by the included operation. Keep that consumption record even when different accounting methods use different factor evidence. A contract or energy-attribute certificate does not replace the quantity, reporting period or boundary of the energy use.

The location-based method uses the relevant grid-average basis. The market-based method uses qualifying contractual information under the applicable rules and data hierarchy. The Scope 2 Guidance publisher page identifies quality criteria for contractual instruments and the need for transparent energy-purchase information. Check the guidance applicable to the inventory instead of assuming that any certificate or supplier claim supports a particular factor.

Location-based accounting uses grid-average data; market-based accounting uses contractual data and quality criteria. Both retain energy consumed.
Keep energy consumption and the two calculation bases distinct.
Diagram text description

The location-based method uses the relevant grid-average basis. The market-based method uses qualifying contractual data subject to the guidance’s quality criteria and data hierarchy. Both retain the actual energy-consumption record. Where dual reporting applies, label the results separately rather than summing them; a certificate does not replace the source quantity.

Where dual reporting applies, retain and label the separate results for the same consumption; do not add them as though they were two energy activities. Record which method produced each result and what evidence supports it.

The fictional 200 kg electricity example is a location-based teaching illustration only. It does not demonstrate a real grid factor or a qualifying market-based result. Contractual evidence has not been assessed, and no renewable-energy or zero-emissions claim follows from the example.

Do not make every Scope 3 number look equally certain

Scope 3 estimates can have different evidence resolution even when displayed in the same emissions unit. A supplier-specific number is not automatically complete or boundary-compatible, while a broad proxy can be useful if its limitation is clear. Retain the method and evidence basis for each contribution.

Input basisWhat it can supportLimitation to disclose
Supplier-specific informationA source- or product-related estimate with its stated coverageCheck period, boundary, allocation and applicability to the purchased quantity
Physical activity with factorsAn estimate linked to mass, distance, nights or other defined activityRetain units, geography, technology assumptions and factor version
Spend-based estimateA modelled proxy where expenditure and model coverage are suitablePrice year, currency, sector and price changes may affect interpretation

Table 3, shown one row at a time. Every field is retained.

Row 1

Input basis
Supplier-specific information
What it can support
A source- or product-related estimate with its stated coverage
Limitation to disclose
Check period, boundary, allocation and applicability to the purchased quantity

Row 2

Input basis
Physical activity with factors
What it can support
An estimate linked to mass, distance, nights or other defined activity
Limitation to disclose
Retain units, geography, technology assumptions and factor version

Row 3

Input basis
Spend-based estimate
What it can support
A modelled proxy where expenditure and model coverage are suitable
Limitation to disclose
Price year, currency, sector and price changes may affect interpretation

Disclose methods, allocation choices, exclusions and the portion based on supplier-specific data, stating how that share was measured. Do not infer an evidence percentage from how many supplier names appear in the file. Keep unresolved categories and uncalculated activity visible rather than presenting every Scope 3 number as equally certain.

For comparisons, preserve the coverage and method history. Moving from a spend proxy to a physical estimate can change the result without proving an operational reduction. Explain the change and prioritize the evidence gap that most affects the decision.

Review the annual inventory before reporting it

Review the annual inventory against both the entity/source register and the supporting records. A total can be arithmetically correct while missing a site, applying an obsolete factor or counting the same activity twice. Reconciliation should expose those issues before the result is reported.

  • Check source and period coverage, including active sites with missing months.
  • Reconcile duplicate invoices, revised records and overlapping supplier totals.
  • Confirm scope/category classification and compatible activity/factor units.
  • Check factor versions, gas coverage, GWP basis and conversion steps.
  • Review estimates, allocations, exclusions and unresolved evidence.
  • Assess boundary, method and data changes against the base-year and recalculation policy.

Keep an inventory management plan describing responsibilities, methods, record locations, review steps and change control. Record who reviewed an exception, what evidence resolved it and which result changed. An unexplained adjustment should not disappear inside a formula or a replaced workbook.

Compare year-on-year movements with operational evidence and the method history. A facility acquisition, corrected unit or new supplier dataset has a different meaning from using less fuel at an unchanged operation. Preserve the original and revised records and explain the treatment. These controls make an inventory more reviewable; they do not themselves constitute an independent assurance opinion.

Follow one utility record from invoice to inventory

This utility trace is entirely fictional. Invoice U-0525, meter M-05, facility HW-A and all quantities, dates, factors and reviewer details are invented. The row illustrates a May 2025 electricity contribution inside Harbour Workshop’s calendar 2025 operational-control inventory. It is not measured company data or a complete annual result.

Trace fieldFilled fictional entryReview or unresolved evidence
Source and periodU-0525; M-05; service 1–31 May 2025Confirm meter and service dates against the original record
Boundary and activityHW-A included; provisional 800 kWh purchased electricityShared-area allocation memo: not supplied
Factor/version and basisELEC-T1; invented 0.25 kg CO2e/kWh; location-based teaching basisNo actual geography-specific factor or contractual evidence established
Calculation800 kWh × 0.25 = 200 kg CO2e = 0.200 tonnesAlready-CO2e coefficient; no further GWP
Reviewer questionDoes M-05 also supply a shared corridor outside HW-A’s assessed boundary?Facilities owner must obtain the meter/landlord allocation evidence
Inventory lineINV-HWA-MAY25; Scope 2; provisional 200 kg CO2eHold final acceptance pending the boundary/allocation answer

Table 4, shown one row at a time. Every field is retained.

Row 1

Trace field
Source and period
Filled fictional entry
U-0525; M-05; service 1–31 May 2025
Review or unresolved evidence
Confirm meter and service dates against the original record

Row 2

Trace field
Boundary and activity
Filled fictional entry
HW-A included; provisional 800 kWh purchased electricity
Review or unresolved evidence
Shared-area allocation memo: not supplied

Row 3

Trace field
Factor/version and basis
Filled fictional entry
ELEC-T1; invented 0.25 kg CO2e/kWh; location-based teaching basis
Review or unresolved evidence
No actual geography-specific factor or contractual evidence established

Row 4

Trace field
Calculation
Filled fictional entry
800 kWh × 0.25 = 200 kg CO2e = 0.200 tonnes
Review or unresolved evidence
Already-CO2e coefficient; no further GWP

Row 5

Trace field
Reviewer question
Filled fictional entry
Does M-05 also supply a shared corridor outside HW-A’s assessed boundary?
Review or unresolved evidence
Facilities owner must obtain the meter/landlord allocation evidence

Row 6

Trace field
Inventory line
Filled fictional entry
INV-HWA-MAY25; Scope 2; provisional 200 kg CO2e
Review or unresolved evidence
Hold final acceptance pending the boundary/allocation answer

The source check connects the invoice with the facility list and meter coverage before accepting the inventory line. A neat multiplication cannot decide whether the shared corridor belongs in this record. Keep 800 kWh and 200 kg as provisional exercise values while requesting the allocation evidence; do not silently subtract an invented share or label the issue resolved.

If the evidence changes the quantity or classification, retain the previous row and record the correction and reviewer disposition. A real application also needs the appropriate published factor and its applicability checked. Organizing these fields makes the calculation traceable, but it does not establish assurance or conformity with every reporting requirement.

An inventory is not a reduction or offset claim

An inventory describes emissions under its stated boundary, methods and evidence. Public disclosure, target setting, abatement and any optional offsetting come after that measurement task and need their own decisions. They cannot silently alter the gross source quantities or scope totals.

Use a reviewed inventory to investigate where emissions arise and what actions might change them. Then evaluate reductions with comparable boundaries, activity and methods. A smaller reported total can reflect a corrected duplicate, changed factor or incomplete coverage rather than a physical reduction; explain the cause before making the claim.

A gross inventory supports reporting, reduction action and an optional offset record; these remain separate activities.
Use the inventory for decisions while keeping gross totals visible.
Diagram text description

A reviewed gross inventory can inform reporting and reduction decisions. An optional offset record is a separate external credit-related activity. None of these downstream actions silently changes the original source quantities or gross scope totals; claims need their own evidence and review.

Keep any credit purchase or retirement in a separate record with the evidence and wording appropriate to that action. It does not make the fictional boiler burn less fuel or remove its 728 kg contribution from the gross inventory. Likewise, a complete-looking report is not a verification opinion.

The Corporate Standard publisher distinguishes corporate inventory accounting from project-credit quantification and from a verification-process standard. Preserve those distinctions when presenting the result. Say what was calculated, what remains provisional and which later claim or decision still needs support. The evidence-backed inventory should remain available for review even when downstream actions are communicated.

Keep product and supplier evidence in context

Product, SKU, bill-of-materials and supplier records can inform some value-chain activity, but they need to be interpreted within the corporate inventory’s boundary and period. A product footprint or supplier total cannot simply be inserted without checking purchased quantity, coverage, allocation and overlap with other records.

Keep the connection explicit: which corporate activity does the record represent, what units and time period does it cover, and what method produced its emissions information? Preserve the original reference and any adjustments used to make it applicable. Record limitations instead of assuming that structured data is already a verified company result.

Choose the next task from the gap in the inventory. Resolve the disputed meter boundary, obtain an appropriate factor, complete a missing source or improve a weak supplier estimate. Whole-company verification and regulatory assurance require their own scope and evidence. A useful accounting process makes those needs visible while keeping the gross inventory, product analysis and later claims distinct.