Corporate Carbon Emission Statements: What a Credible Report Needs to Show
A person holds an open report with illustrative charts. The desk also holds facility and utility images, a miniature plant and a mug.
Diagram text description
A corporate carbon emission statement reports greenhouse gas emissions for a named organization and period. It should give the reader enough information to work out which operations and activities are covered, how the numbers were calculated and what evidence still needs review. One headline number can help a reader find the result. The statement makes that result interpretable by putting the boundary, scope, method and status next to it.
Consider a fictional manufacturer, Gannet Ridge Ceramics. Its draft includes two controlled facilities, two alternative figures for purchased electricity and two selected value-chain categories. It also has an estimated refrigerant line and a credit purchase with retirement still unconfirmed. Each belongs in a different part of the statement. A reader can understand the result without treating the estimate as measured, the purchase as a deduction or the internal checks as assurance.
The filled statement later in this article uses the same facts throughout. Read it as a case in how to record the figures and their limits, then follow the records behind any line you intend to use.
Start with the company and reporting period
Put the legal reporting entity and the first and last dates of the emissions period near the top. The business name on a cover may refer to several entities, a division or a brand. The inventory file should identify which entity is making the statement and which operations it consolidates. That prevents a reader from comparing a division’s result with the full group or attributing a change to the wrong entity.
In this fictional case, Gannet Ridge Ceramics Ltd reports for 1 January through 31 December 2025. Kiln Works and Packing Hall are the two included operations under its chosen consolidation approach. The reporting file is GR-25 v0.4. Its release status is draft, pending the refrigerant evidence review. Its comparison uses a restated 2022 base. Those dates describe the company’s fictional reporting periods. The annual statement should also distinguish the inventory period from the date of sign-off once that decision exists.
Check activity records against the period before copying a figure into the statement. If a year-end utility bill contains January consumption, keep the bill and reconcile it to the meter period rather than assigning all consumption to its invoice date. A change to the reporting entity, dates or consolidation basis should be visible in the next version.
Show the organizational boundary
The organizational boundary identifies which operations enter the inventory. Equity share uses the organization’s economic interest. Financial control and operational control look at different forms of control. State the chosen basis in the disclosure and retain the source records that explain how it applies to each operation. An ownership percentage alone may not settle an operational-control decision.
Gannet Ridge uses operational control. It runs the production policies at Kiln Works and Packing Hall, both included for the full fictional 2025 period. Its separately managed joint-venture depot sits outside the operational-control boundary because the joint venture directs the depot’s operations. The diagram shows the result for this case. The company records the depot decision separately and checks whether activity connected with it needs a value-chain assessment.
The frame encloses Kiln Works and Packing Hall, the operations controlled by the fictional company. The separately managed joint-venture depot remains outside this consolidation boundary and is disclosed separately.
Diagram text description
This is particularly important when an arrangement changes. Gannet Ridge took control of Packing Hall at the start of 2025. The hall already operated in 2022 under the previous owner. For current reporting, the facilities schedule records the date control began. For the base-year comparison, the inventory lead uses the company’s recalculation policy and the hall’s historic records to determine how to restate the old perimeter.
A reviewer should be able to connect every included site with its utility and operating records, and every exclusion with the rule that produced it. If a leased operation’s responsibility changes, update that decision before rolling its bills into the next year’s inventory.
Show activities and scope coverage
After deciding which operations to consolidate, classify the activities. Scope 1 covers direct emissions from sources the company owns or controls under its chosen approach. Scope 2 covers generation emissions associated with energy it buys or acquires and consumes. Scope 3 concerns other indirect emissions in the value chain. A scope name is more informative when the disclosure says which activities produced the figure.
| Case activity | Reporting line | What the line covers |
|---|---|---|
| Kiln fuel, controlled fleet and refrigerant losses | Scope 1 | Combustion and fugitive sources at the controlled operations |
| Purchased electricity at Kiln Works and Packing Hall | Scope 2 | Generation emissions for the same purchased electricity under the two applicable methods |
| Purchased ceramic inputs | Scope 3, purchased goods and services | Selected supplier production emissions for the materials recorded |
| Contracted inbound freight | Scope 3, upstream transportation and distribution | Selected third-party inbound movements into the controlled sites |
Table 1, shown one row at a time. Every field is retained.
Row 1
- Case activity
- Kiln fuel, controlled fleet and refrigerant losses
- Reporting line
- Scope 1
- What the line covers
- Combustion and fugitive sources at the controlled operations
Row 2
- Case activity
- Purchased electricity at Kiln Works and Packing Hall
- Reporting line
- Scope 2
- What the line covers
- Generation emissions for the same purchased electricity under the two applicable methods
Row 3
- Case activity
- Purchased ceramic inputs
- Reporting line
- Scope 3, purchased goods and services
- What the line covers
- Selected supplier production emissions for the materials recorded
Row 4
- Case activity
- Contracted inbound freight
- Reporting line
- Scope 3, upstream transportation and distribution
- What the line covers
- Selected third-party inbound movements into the controlled sites
The fictional fleet burns fuel in vehicles Gannet Ridge controls. The independent haulier moves purchased inputs using its own vehicles. Putting the two fuel uses on different lines preserves the boundary and helps prevent double counting. Similarly, the purchased electricity powers both plants, while the direct fuel burned in the kiln is already part of the direct line.
The selected value-chain rows do not cover all activities. Purchased capital equipment and downstream life-cycle categories were not assessed for the case. Give those limitations beside the selected results so a reader can distinguish what is quantified from what remains outside the disclosed coverage.
Report scope 1 and scope 2 separately
Report direct and purchased-energy results as separate gross figures. A corporate statement prepared in accordance with the GHG Protocol Corporate Standard needs distinct Scope 1 and Scope 2 reporting. The reporting template provides separate scope rows. The published Scope 2 guidance explains when two purchased-energy views are needed. Keep these accounting fields independent of transactions in offsets or allowances.
| Gross inventory line | Fictional 2025 amount | Reading note |
|---|---|---|
| Scope 1 | 540 t CO2e | Includes 520 from stationary fuel, 15 from the controlled fleet and a provisional 5 from refrigerants |
| Scope 2, location-based | 290 t CO2e | Uses the grid basis for the purchased electricity |
| Scope 2, market-based | 255 t CO2e | Uses qualifying data and residual mix for the same activity |
| Scope 1 plus location-based Scope 2 | 830 t CO2e | One combined view of the two scopes |
| Scope 1 plus market-based Scope 2 | 795 t CO2e | An alternative combined view with the same direct emissions |
Table 2, shown one row at a time. Every field is retained.
Row 1
- Gross inventory line
- Scope 1
- Fictional 2025 amount
- 540 t CO2e
- Reading note
- Includes 520 from stationary fuel, 15 from the controlled fleet and a provisional 5 from refrigerants
Row 2
- Gross inventory line
- Scope 2, location-based
- Fictional 2025 amount
- 290 t CO2e
- Reading note
- Uses the grid basis for the purchased electricity
Row 3
- Gross inventory line
- Scope 2, market-based
- Fictional 2025 amount
- 255 t CO2e
- Reading note
- Uses qualifying data and residual mix for the same activity
Row 4
- Gross inventory line
- Scope 1 plus location-based Scope 2
- Fictional 2025 amount
- 830 t CO2e
- Reading note
- One combined view of the two scopes
Row 5
- Gross inventory line
- Scope 1 plus market-based Scope 2
- Fictional 2025 amount
- 795 t CO2e
- Reading note
- An alternative combined view with the same direct emissions
The three direct source amounts are illustrative inventory inputs. They reconcile to 540 tonnes of carbon dioxide equivalent, written as t CO2e. The refrigerant estimate is already inside that result and therefore affects both combined views. Carry the estimate flag wherever the subtotals appear.
A reader who wants to compare the physical energy activity can start with the megawatt-hours. A reader who needs a combined emissions figure should identify the applicable Scope 2 basis before using either subtotal. Adding the two purchased-energy figures would count the same consumption twice.
Describe purchased-energy method clearly
The published Scope 2 Guidance executive summary calls for both methods when a company has operations in a market that provides product- or supplier-specific contractual data. The trigger concerns what the market provides, even if the company has no eligible instruments for some of its own consumption. The location-based method uses grid emissions data for the place where the energy is consumed. The market-based method follows the hierarchy of applicable contractual and fallback data.
For the fictional 1,000 MWh, qualifying contractual data cover 250 MWh. Gannet Ridge uses an available residual-mix factor for the other 750 MWh. The diagram keeps the total activity constant and shows where the market method splits it. The factors are invented for this exercise.
The upper bar shows all 1,000 megawatt-hours under the location-based grid method. The lower bar splits the same electricity into 250 megawatt-hours with qualifying contractual data and 750 with residual-mix fallback. The two results stay separate.
Diagram text description
| Method and coverage | Activity and factor | Fictional result |
|---|---|---|
| Location-based, all purchased electricity | 1,000 MWh × 0.290 t CO2e per MWh | 290 t CO2e |
| Market-based, qualifying share | 250 MWh × 0.120 t CO2e per MWh | 30 t CO2e |
| Market-based, uncovered share | 750 MWh × 0.300 t CO2e per MWh using the residual mix | 225 t CO2e |
| Market-based, total | 30 + 225 t CO2e | 255 t CO2e |
Table 3, shown one row at a time. Every field is retained.
Row 1
- Method and coverage
- Location-based, all purchased electricity
- Activity and factor
- 1,000 MWh × 0.290 t CO2e per MWh
- Fictional result
- 290 t CO2e
Row 2
- Method and coverage
- Market-based, qualifying share
- Activity and factor
- 250 MWh × 0.120 t CO2e per MWh
- Fictional result
- 30 t CO2e
Row 3
- Method and coverage
- Market-based, uncovered share
- Activity and factor
- 750 MWh × 0.300 t CO2e per MWh using the residual mix
- Fictional result
- 225 t CO2e
Row 4
- Method and coverage
- Market-based, total
- Activity and factor
- 30 + 225 t CO2e
- Fictional result
- 255 t CO2e
Check that the contractual evidence conveys the relevant emissions attribute, is exclusive, and was tracked and retired, cancelled or redeemed for the reporting entity as applicable. Match the instrument to the consumption period and market. Check additional criteria for supplier-specific rates or direct arrangements when those apply. A draft schedule offering more volume is insufficient if the site account or covered period cannot be matched.
For uncovered consumption, check the applicable hierarchy for other qualifying product or supplier data, then a residual mix where available. If qualifying contractual data and a residual mix are unavailable, the executive summary allows location-based data as a fallback in the market-based hierarchy. Record which factor was used and disclose the absence of a residual mix where relevant. Energy attributes determine a rate for purchased energy. Carbon offset purchases have a separate purpose and record.
Label gases units and CO2e
Label the physical gas and the equivalent result clearly. Carbon dioxide, methane, nitrous oxide, hydrofluorocarbons, perfluorocarbons, sulphur hexafluoride and nitrogen trifluoride are the seven gases or gas groups named by the Corporate Standard overview and the February 2013 amendment. The corporate reporting amendment calls for separate gas data in metric tonnes and in tonnes of carbon dioxide equivalent. The Scope 3 amendment calls for category totals in carbon dioxide equivalent and does not require a separate published row for each gas in every category.
To see the unit change, take a separate fictional teaching example of 2 kg of methane. Multiplying by an illustrative factor of 30 gives 60 kg CO2e. Divide that result by 1,000 to obtain 0.060 t CO2e. The physical methane remains 2 kg. The diagram separates that mass from its converted equivalent. This arithmetic is a teaching illustration and supplies no factor to the company statement.
The first quantity is physical methane mass. Thirty is the illustrative multiplier used only in this teaching calculation. The result is 60 kilograms of carbon dioxide equivalent, or 0.060 tonnes. The reporting inventory uses its documented IPCC basis.
Diagram text description
The February 2013 amendment specifies 100-year IPCC global warming potentials. It recommends the most recent assessment report and requires one assessment where possible. Disclose the source and whether multiple reports were used. For this fictional inventory, assume Gannet Ridge’s controlled factor register names the IPCC Fifth Assessment Report’s 100-year basis, applied consistently to the current period and restated base. The choice is visible to the reviewer.
If a supplier factor is already expressed in kilograms of carbon dioxide equivalent per unit, multiply it by activity in matching units. Convert kilograms to tonnes if required. Applying a warming potential again would convert a quantity that is already in equivalent terms. Keep any applicable separately reported biogenic carbon dioxide outside the gross scope rows, with its own physical unit and supporting record.
Make the calculation reproducible
Reproducibility starts with a path from each reported line to a dated activity record and a versioned method. An annual total can add up correctly while the evidence for one input remains open. The inventory analyst needs to be able to reopen a line, reproduce the calculation and see who controls the input. Gannet Ridge uses the following example records for its draft.
| Report line | Activity and calculation basis | Owner and review decision |
|---|---|---|
| Location-based electricity | GR-METER25 v2 records 1,000 MWh for the two sites. GR-POWER v1 gives the illustrative grid factor of 0.290 t CO2e per MWh. Activity × factor gives 290 t CO2e. | Energy analyst matches site, meter, period and factor version before carrying the line forward. |
| Market-based electricity | Same meter file. GR-ATTR v2 assigns 250 MWh to qualifying data and GR-POWER v1 supplies the residual mix for 750 MWh. | Procurement and energy analyst reconcile the evidence and shares to 1,000 MWh before approving the method record. |
| Refrigerant estimate | GR-REF25 v0.2 records the service estimate equivalent to 5 t CO2e. Closing cylinder weights are missing. | Facilities lead obtains the cylinder record. Inventory reviewer tests the estimate or recalculates the direct line. |
Table 4, shown one row at a time. Every field is retained.
Row 1
- Report line
- Location-based electricity
- Activity and calculation basis
- GR-METER25 v2 records 1,000 MWh for the two sites. GR-POWER v1 gives the illustrative grid factor of 0.290 t CO2e per MWh. Activity × factor gives 290 t CO2e.
- Owner and review decision
- Energy analyst matches site, meter, period and factor version before carrying the line forward.
Row 2
- Report line
- Market-based electricity
- Activity and calculation basis
- Same meter file. GR-ATTR v2 assigns 250 MWh to qualifying data and GR-POWER v1 supplies the residual mix for 750 MWh.
- Owner and review decision
- Procurement and energy analyst reconcile the evidence and shares to 1,000 MWh before approving the method record.
Row 3
- Report line
- Refrigerant estimate
- Activity and calculation basis
- GR-REF25 v0.2 records the service estimate equivalent to 5 t CO2e. Closing cylinder weights are missing.
- Owner and review decision
- Facilities lead obtains the cylinder record. Inventory reviewer tests the estimate or recalculates the direct line.
The electricity calculation multiplies MWh by tonnes per MWh, which leaves tonnes. The calculation file must also state how any source in kilograms was converted before aggregation. Store the report version, data owner and method together, so a reviewer can locate the record that changed when a figure is revised. For a material change, document which total and comparison inherited the revised value.
List exclusions and data limits
Give each limitation a status that tells the reader what happened. A source outside the consolidation boundary, an in-boundary source with estimated data and an assessed non-relevant activity have different consequences. The choice affects both completeness and what a reviewer should request. Gannet Ridge uses these examples in its fictional register.
| Status | Fictional example | Decision and evidence needed |
|---|---|---|
| Outside the organizational boundary | Joint-venture depot is managed by a different operator. | Document the control decision. Assess connected value-chain activity separately. |
| In-boundary estimate | Refrigerant service estimate included at 5 t CO2e. Closing cylinder weights are missing. | Keep the estimate flagged and obtain the closing weights before sign-off. |
| Assessed non-relevance | Site equipment and utility records show no purchased steam at either controlled facility. | Record why the activity is non-relevant. Reopen if a steam supply is added. |
| Unassessed category | Downstream use is outside the selected Scope 3 work. | Disclose the omission and leave the category unquantified. |
Table 5, shown one row at a time. Every field is retained.
Row 1
- Status
- Outside the organizational boundary
- Fictional example
- Joint-venture depot is managed by a different operator.
- Decision and evidence needed
- Document the control decision. Assess connected value-chain activity separately.
Row 2
- Status
- In-boundary estimate
- Fictional example
- Refrigerant service estimate included at 5 t CO2e. Closing cylinder weights are missing.
- Decision and evidence needed
- Keep the estimate flagged and obtain the closing weights before sign-off.
Row 3
- Status
- Assessed non-relevance
- Fictional example
- Site equipment and utility records show no purchased steam at either controlled facility.
- Decision and evidence needed
- Record why the activity is non-relevant. Reopen if a steam supply is added.
Row 4
- Status
- Unassessed category
- Fictional example
- Downstream use is outside the selected Scope 3 work.
- Decision and evidence needed
- Disclose the omission and leave the category unquantified.
The facilities lead should obtain the signed cylinder log, check the opening and closing weights and compare the record with service additions and returns. If the reconciliation changes the amount, amend the refrigerant line and every subtotal that uses it. If records cannot be recovered, the reviewer needs an explicit decision on the estimate and its uncertainty.
A field left blank gives readers no way to tell whether the team checked it. State the evidence behind a non-relevant decision and keep unassessed or missing activity visible. This lets readers understand why the report covers a line without assuming that all other sources were zero.
Keep the base year comparable
A base-year comparison needs the same boundary and calculation basis, or a transparent record of differences. Gannet Ridge’s originally reported 2022 location-based Scope 1 plus Scope 2 subtotal was 800 t CO2e. Packing Hall was already operating in 2022 but was acquired at the start of the fictional 2025 reporting year. Its historic comparable emissions amount to an illustrative 80 t CO2e under the restatement basis.
Apply the company’s base-year policy to that structural change. Add 80 t CO2e to the original base, giving 880 t CO2e for 2022 on the revised boundary. Compare the draft 2025 location-based subtotal of 830 t CO2e with that restated base. The change is −50 t CO2e, about −5.7% relative to 880. The figure shows these as different steps. The first changes the earlier perimeter. The second compares periods on the resulting basis.
Add 80 tonnes for the historically operated Packing Hall to restate the fictional 2022 location-based subtotal from 800 to 880 tonnes of carbon dioxide equivalent. Compare 2025 with the restated base. The 2025 draft subtotal is 830 tonnes, a difference of 50 tonnes.
Diagram text description
Keep both base-year versions and record why the restatement was triggered. The fictional base file GR-BASE22 v2 contains the added historic facility amount and uses the same scope coverage and GWP basis as the current comparison. If later review reveals a factor change or an error in the historic meter data, document it and reassess the trend.
The difference between the two comparable totals still requires explanation. The reviewer would check production volume, fuel, electricity and factor changes before attributing it to operations. The open refrigerant estimate makes the 2025 comparison provisional, and the location-based comparison says nothing about a market-based trend without a matching market-based base.
Keep gross emissions apart from trades
Carry gross scope totals forward independently of purchases, sales, transfers or retirements. The fictional finance ledger records a purchase of 50 credit units, described in the invoice as one tonne of carbon dioxide equivalent each. The inventory still reports 830 t CO2e on the location-based Scope 1 plus Scope 2 basis. A separate record can describe the transaction and the evidence about the unit status.
The draft communications line says “Our operations emitted 780 tonnes after offsets.” The proposed figure subtracts 50 from the location-based subtotal even though the registry retirement is unresolved. The reviewer should retain the 830 t CO2e gross subtotal with its boundary and refrigerant qualification, and keep the 50 units in a separate purchase record. The figure shows the open step from purchase to retirement evidence.
The fictional gross Scope 1 plus location-based Scope 2 subtotal is 830 tonnes of carbon dioxide equivalent. The separate trade ledger shows 50 purchased units and an unresolved retirement check. The purchase makes no change to the gross inventory.
Diagram text description
| Reconciliation step | Fictional evidence in hand | Owner and decision |
|---|---|---|
| Match the inventory figure | 540 t Scope 1 and 290 t location-based Scope 2 reconcile to 830 t CO2e on the stated basis. | Inventory lead retains the gross figure with the estimate flag and separate market-based view. |
| Match the credit transaction | Invoice GR-CREDIT25 v1 records 50 units. No registry retirement statement is supplied. | Procurement requests serials, registry status, retirement date, beneficiary and purpose. Hold any completed-use statement. |
| Check the exact public wording | Proposed 780-tonne wording combines an inventory subtotal with a purchase. | Claims reviewer holds the wording and checks the exact proposed replacement after reviewing the registry and inventory files. |
Table 6, shown one row at a time. Every field is retained.
Row 1
- Reconciliation step
- Match the inventory figure
- Fictional evidence in hand
- 540 t Scope 1 and 290 t location-based Scope 2 reconcile to 830 t CO2e on the stated basis.
- Owner and decision
- Inventory lead retains the gross figure with the estimate flag and separate market-based view.
Row 2
- Reconciliation step
- Match the credit transaction
- Fictional evidence in hand
- Invoice GR-CREDIT25 v1 records 50 units. No registry retirement statement is supplied.
- Owner and decision
- Procurement requests serials, registry status, retirement date, beneficiary and purpose. Hold any completed-use statement.
Row 3
- Reconciliation step
- Check the exact public wording
- Fictional evidence in hand
- Proposed 780-tonne wording combines an inventory subtotal with a purchase.
- Owner and decision
- Claims reviewer holds the wording and checks the exact proposed replacement after reviewing the registry and inventory files.
Even if the units are later retired, the retirement evidence would support a fact about those units, subject to its scope and intended use. The gross rows would still describe emissions from the covered sources. Keep any public-use decision separate from the inventory arithmetic and identify which claim the evidence can support.
Show exactly what scope 3 covers
Name the value-chain activities actually quantified. Gannet Ridge includes 190 t CO2e for selected purchased ceramic inputs and 35 t CO2e for contracted inbound freight. The disclosed subtotal is 225 t CO2e for those two categories. A reader can compare that subtotal only with a result that covers the same types of activity on a comparable basis.
For materials, the fictional calculation matches purchased masses to supplier factory-gate factors for the defined inputs. Procurement checks the supplier process boundary and unit before using a factor. For the inbound freight line, the example uses distance and shipment mass with an illustrative transport-factor register. The team confirms that the supplier factors exclude the inbound movement into Gannet Ridge’s plants, so the separate 35 t CO2e line does not duplicate it. If a supplier factor includes the route, the analyst reconciles the overlap before adding the lines.
These figures leave purchased capital equipment and downstream categories unassessed. Changes in supplier coverage or method could also change the result without a corresponding change in physical activity. Put the coverage and uncertainty next to the 225 t CO2e figure. A reporting programme or obligation may require different coverage. The example’s narrow value-chain subtotal cannot establish that a broader requirement has been met.
State what was reviewed and by whom
State which review occurred, which information it covered and which conclusion the evidence supports. The Corporate Standard overview explains that a verifiable inventory can be developed under the accounting standard. A verification process has its own criteria, work and statement. The format of a corporate report cannot supply evidence of an engagement.
| Review status | Evidence to look for | How to describe the status |
|---|---|---|
| Internal review | Dated reconciliation, named reviewers and open actions | Describe the internal checks actually completed and what remains open. |
| Independent assurance or verification | Provider’s statement with scope, criteria, period, conclusion and any limits | Describe that engagement and identify the figures it covered. |
| No independent assurance | No provider statement for the report | State that the report has no independent assurance. |
Table 7, shown one row at a time. Every field is retained.
Row 1
- Review status
- Internal review
- Evidence to look for
- Dated reconciliation, named reviewers and open actions
- How to describe the status
- Describe the internal checks actually completed and what remains open.
Row 2
- Review status
- Independent assurance or verification
- Evidence to look for
- Provider’s statement with scope, criteria, period, conclusion and any limits
- How to describe the status
- Describe that engagement and identify the figures it covered.
Row 3
- Review status
- No independent assurance
- Evidence to look for
- No provider statement for the report
- How to describe the status
- State that the report has no independent assurance.
Gannet Ridge’s analyst has checked the arithmetic, including the separate electricity views and the selected value-chain subtotal. The inventory lead has not closed the refrigerant estimate, and there is no independent assurance engagement for the fictional draft. An appropriate status line is “Internal arithmetic check completed. Evidence review remains open. No independent assurance.”
If an assurance statement is later available, verify its exact scope before copying its conclusion. An engagement covering Scope 1 and one method of Scope 2 may leave the alternative view, selected Scope 3 categories, base-year restatement or public claim outside its scope. Keep those limits beside the report’s review statement.
Read a filled corporate emissions statement
This is an explicitly fictional company-year statement for Gannet Ridge Ceramics Ltd. The table consolidates the reporting choices above and uses invented inputs. It shows what a reader needs to interpret the figures and what would change them. It is a draft excerpt for review.
| Statement field | Filled fictional disclosure | Evidence or decision |
|---|---|---|
| Entity, period and version | Gannet Ridge Ceramics Ltd, 1 January through 31 December 2025. GR-25 v0.4. | Internal arithmetic check complete. Evidence review and sign-off pending. |
| Consolidation and operations | Operational control. Kiln Works and Packing Hall included. Joint-venture depot outside the organizational boundary. | Facilities schedule records control dates and the depot decision. |
| Scope 1 gross | 540 t CO2e. Stationary fuel 520, controlled fleet 15 and refrigerants 5. | Refrigerant amount estimated. Facilities lead requests closing cylinder records. |
| Scope 2 gross | 290 t CO2e location-based and 255 t CO2e market-based. | Same 1,000 MWh. Grid factor for all in the first view. Qualifying 250 MWh and residual mix for 750 MWh in the second. |
| Scope 1 plus Scope 2 | 830 t CO2e using location-based Scope 2 or 795 t CO2e using market-based Scope 2. | Present as two alternatives. Carry the Scope 1 estimate into both. |
| Selected Scope 3 | 225 t CO2e. Purchased ceramic inputs 190 and contracted inbound freight 35. | Capital equipment and downstream categories unassessed. Subtotal covers the selected activities only. |
| Base year comparison | 2022 location-based base restated from 800 to 880 t CO2e after adding historic Packing Hall activity. 2025 draft 830 t CO2e. | Same stated basis. Difference −50 t CO2e, about −5.7%. No market-based trend presented. |
| Calculation and GWP basis | Versioned activity and factor records. Fictional 100-year IPCC Fifth Assessment Report basis for current and restated periods. | Maintain individual gas and equivalent quantities in the inventory schedules. |
| Trades and assurance | 50 credit units purchased separately. Retirement unconfirmed. No independent assurance. | Hold the proposed after-offset statement. Carry gross inventory independently of the purchase. |
Table 8, shown one row at a time. Every field is retained.
Row 1
- Statement field
- Entity, period and version
- Filled fictional disclosure
- Gannet Ridge Ceramics Ltd, 1 January through 31 December 2025. GR-25 v0.4.
- Evidence or decision
- Internal arithmetic check complete. Evidence review and sign-off pending.
Row 2
- Statement field
- Consolidation and operations
- Filled fictional disclosure
- Operational control. Kiln Works and Packing Hall included. Joint-venture depot outside the organizational boundary.
- Evidence or decision
- Facilities schedule records control dates and the depot decision.
Row 3
- Statement field
- Scope 1 gross
- Filled fictional disclosure
- 540 t CO2e. Stationary fuel 520, controlled fleet 15 and refrigerants 5.
- Evidence or decision
- Refrigerant amount estimated. Facilities lead requests closing cylinder records.
Row 4
- Statement field
- Scope 2 gross
- Filled fictional disclosure
- 290 t CO2e location-based and 255 t CO2e market-based.
- Evidence or decision
- Same 1,000 MWh. Grid factor for all in the first view. Qualifying 250 MWh and residual mix for 750 MWh in the second.
Row 5
- Statement field
- Scope 1 plus Scope 2
- Filled fictional disclosure
- 830 t CO2e using location-based Scope 2 or 795 t CO2e using market-based Scope 2.
- Evidence or decision
- Present as two alternatives. Carry the Scope 1 estimate into both.
Row 6
- Statement field
- Selected Scope 3
- Filled fictional disclosure
- 225 t CO2e. Purchased ceramic inputs 190 and contracted inbound freight 35.
- Evidence or decision
- Capital equipment and downstream categories unassessed. Subtotal covers the selected activities only.
Row 7
- Statement field
- Base year comparison
- Filled fictional disclosure
- 2022 location-based base restated from 800 to 880 t CO2e after adding historic Packing Hall activity. 2025 draft 830 t CO2e.
- Evidence or decision
- Same stated basis. Difference −50 t CO2e, about −5.7%. No market-based trend presented.
Row 8
- Statement field
- Calculation and GWP basis
- Filled fictional disclosure
- Versioned activity and factor records. Fictional 100-year IPCC Fifth Assessment Report basis for current and restated periods.
- Evidence or decision
- Maintain individual gas and equivalent quantities in the inventory schedules.
Row 9
- Statement field
- Trades and assurance
- Filled fictional disclosure
- 50 credit units purchased separately. Retirement unconfirmed. No independent assurance.
- Evidence or decision
- Hold the proposed after-offset statement. Carry gross inventory independently of the purchase.
This format lets a reader reproduce the totals and identify the next review. The provisional refrigerant line affects both combined views. The retirement gap affects the credit-use wording. The value-chain exclusion affects coverage. Treating those as distinct decisions makes the statement useful even before it is ready for release.
Assign an owner to each evidence decision
Assign someone to maintain each line and the evidence behind it. The inventory lead owns the statement version and the relationship between the summary and the supporting schedules. Facilities owns the refrigerant source records. Procurement owns the electricity attribute and credit documents. The reviewer responsible for public wording needs access to the exact approved figures and their limits.
For Gannet Ridge, keep the signed cylinder log with GR-REF25 v0.2 and record the decision on the replacement value or estimate in the next version. If the input changes, trace it through the Scope 1 line, both combined subtotals and the comparison with the restated base. The reviewer can then see how a single missing record affects several outputs without treating every other source as open.
Keep the restatement worksheet and trade ledger linked to the same statement version. When a new credit record arrives, it can update the separate transaction decision without changing the gross figures. Recording responsibility at line level gives the next reviewer a direct route to the right file and a clear reason for any change.
Publish a statement readers can interrogate
Gannet Ridge can use its draft internally with the controlled operations, covered activities, Scope 2 bases and open items attached. The 830 t CO2e location-based subtotal can guide a discussion about the included operations, and the alternative 795 t CO2e subtotal remains available on its own basis. Both carry the same direct estimate. The selected 225 t CO2e value-chain subtotal answers a narrower question.
The next decision
Before external release, have the facilities lead reconcile the cylinder records and the inventory lead update the affected totals and trend. Have procurement resolve the registry question separately before any wording about use of the credits is considered. If evidence is still missing, preserve the qualification and keep the relevant statement on hold. The report should give a reader the exact figures, limits and owners needed to understand what was counted and which decision is still open.
Company carbon accounting