A woman at a desk reviews printed papers beside a laptop, with equipment sketches pinned to a board behind her.
Keep the source records beside the calculation they support.
Diagram text description

A synthetic editorial scene shows a woman reviewing papers beside a laptop with equipment sketches behind her. No legible activity quantity, factor value, customer identifier, inventory total or assurance result is visible.

A Scope 1 GHG emissions calculation starts with a list of direct sources inside a defined organisational boundary. For each source, establish the activity, choose a compatible factor and method, convert individual gas masses to CO₂e where necessary, then add compatible source results. Purchased electricity and upstream fuel production belong on their separate accounts.

The evidence trail matters as much as the multiplication. A controlled source ID should connect the original activity record with its gas, method and factor version. Keep conversions, exceptions and the reviewer’s decision with that line before carrying it into the company total. A number detached from those records is difficult to reproduce or interpret.

A controlled source activity record leads through gas, method and factor version to review and a company total.
Keep each controlled source traceable before adding its result.
Diagram text description

Start with the controlled source ID and its primary activity record. Retain the gas, source-specific method and factor version. Record exceptions and the reviewer decision before adding compatible source CO₂e values to the company total.

This guide follows that sequence using a fictional workshop. Its numerical example deliberately uses invented activity values, factors and hypothetical GWP multipliers to expose the unit logic. It is not a customer footprint or a factor set for a real inventory. The reusable reconstruction record gives you a place to retain the actual evidence and unresolved questions for your own sources.

Define the entity and reporting period first

For the fictional Alder Works workshop, define the reporting entity, the site and the calendar year 2025 before collecting quantities. The example applies operational control consistently to its boiler, van, cooling unit and process. Each source record identifies the equipment or process, relevant gas and dates covered. Those assumptions determine what enters the worked total; arithmetic cannot decide the boundary afterwards.

Suppose a van changes operator during the year. Check the entity, operational-control transfer date, source record and period of use rather than assigning every fuel invoice to whoever paid it. Activity before and after the transfer may need separate records. An invoice issued in January can relate to fuel used in December, so the payment date alone does not establish the emissions period.

Apply the chosen consolidation approach across the inventory. A leased asset needs its actual contract and control facts; a lease label does not by itself settle every scope decision. Record any uncertainty before allocating activity to a company total.

Also distinguish an annual source register from the inventory result. An asset may exist throughout the year while the reporting company controls it for only part of that period. Preserve the inclusion dates and allocation basis so the reviewer can test the quantity against the stated boundary.

Make the source register complete

Build the register around physical sources and their mechanisms. The four families below require different records even when they appear at one workshop. The entries are fictional source identities; they illustrate how to organise the inventory rather than establish which equipment any real business operates.

Source ID and familyActivity neededMethod distinction
B-01, stationary combustionFuel actually burned by the controlled boilerMatch fuel and combustion application; retain individual-gas or CO₂e factor basis
V-01, mobile combustionFuel used by the controlled van, or supported distance under the selected methodVehicle and fuel evidence must match the chosen transport factor
C-01, fugitive releaseIdentified gas released from the cooling unitReconcile service, stock and recovery evidence; a purchase is not automatically a release
P-01, chemical processProcess input, output or material flow required by its methodDistinguish process reaction emissions from fuel used to provide heat

Table 1, shown one row at a time. Every field is retained.

Row 1

Source ID and family
B-01, stationary combustion
Activity needed
Fuel actually burned by the controlled boiler
Method distinction
Match fuel and combustion application; retain individual-gas or CO₂e factor basis

Row 2

Source ID and family
V-01, mobile combustion
Activity needed
Fuel used by the controlled van, or supported distance under the selected method
Method distinction
Vehicle and fuel evidence must match the chosen transport factor

Row 3

Source ID and family
C-01, fugitive release
Activity needed
Identified gas released from the cooling unit
Method distinction
Reconcile service, stock and recovery evidence; a purchase is not automatically a release

Row 4

Source ID and family
P-01, chemical process
Activity needed
Process input, output or material flow required by its method
Method distinction
Distinguish process reaction emissions from fuel used to provide heat

Check stationary boilers and generators, fleet and other mobile equipment, refrigerant or industrial-gas sources, and relevant chemical processes separately. A fuel ledger does not prove the fugitive register is complete, and a maintenance list may omit a process source. Compare the source list with site and asset records and name any activity still awaiting assessment.

Assign one stable ID to the physical source or calculation account. If two teams supply evidence for the same boiler, link both records to B-01 rather than creating two emissions sources.

Collect activity data appropriate to each source

Use activity data that represents the mechanism being calculated. Boiler combustion needs fuel use; a vehicle method may use fuel or an appropriate distance measure; refrigerant loss needs service and movement evidence; a process calculation needs its specified material or production basis. These inputs should retain their original units and source references.

  • Boiler: collect fuel meter or consumption records and any tank reconciliation needed to establish use.
  • Vehicle: retain fuel transactions linked to the vehicle, or distance and vehicle information required by the selected method.
  • Fugitive gas: collect gas identity, additions, recovery, stock changes and the basis for the release estimate.
  • Process: retain the material input, output, composition or production quantity required by that process method.

An expenditure line is not automatically a physical fuel quantity. Where a supported method estimates activity, preserve its assumptions instead of presenting the estimate as a meter reading. Similarly, do not replace vehicle fuel data with a distance factor merely because another spreadsheet already contains kilometres.

Record which reporting period each quantity covers. Retain meter identifiers, delivery references or service-sheet dates so that partial periods and corrections can be reconciled. A single spreadsheet column labelled “quantity” needs a companion unit and activity description; otherwise 500 litres, 500 kilometres and 500 kilograms can look identical while requiring entirely different factors.

Do not equate purchases or charges with releases

Purchases, stock and use are different quantities. In a fictional fuel account with no transfers, 100 L in the opening tank plus 1,100 L delivered minus 200 L closing stock gives 1,000 L used. The 1,100 L purchase is not the combustion activity for that period. Check transfers and other movements before applying this simplified reconciliation to a real tank.

Refrigerant needs its own account. A 5 kg purchase might become cylinder stock, installation charge, service additions or another transfer; it is not automatically a 5 kg atmospheric release. Installed charge remaining in equipment is also stock. Recovered gas must have a recorded destination and cannot simultaneously be counted as both a release and retained stock. The worked example assumes a separately supported fictional 2 kg release, not a release inferred from the purchase.

The distinction matters when a contractor supplies both gas and service. An invoice and a service sheet may describe one addition, not two movements. Link them to the same equipment event. If the released quantity or gas identity is missing, retain that gap and choose an appropriate estimation method when the necessary data are available.

Do not silently enter zero to keep the total complete. Separate the known activity from the unresolved source and explain how the gap affects the provisional result.

Choose gas-specific factors with matching units

A factor must describe the source as well as match its unit. Retain the fuel or gas, technology or application, denominator, emissions boundary, geography and version or year basis. A litre-based factor for one fuel is not interchangeable with a litre-based factor for another. Matching symbols are necessary but insufficient.

Compare the activity record and factor record field by field. If the activity is in litres and the factor is per kilogram, use a supported conversion such as the applicable density, or obtain a compatible factor. Do not assume one litre equals one kilogram. Also check whether the factor covers direct combustion only or includes upstream production that belongs outside the direct line.

Activity and factor records show matching source and gas, unit and boundary, place and period fields.
Match source, gas, units, boundary, place and period.
Diagram text description

Compare the activity with the factor source and gas, denominator unit, emissions boundary, applicable geography and reporting-year basis. A matching number format or unit alone does not establish that the factor describes the right source.

Read the output unit carefully. A factor expressed as kilograms of CO₂, grams of CH₄ or grams of N₂O returns a gas-specific mass. A factor expressed as kilograms of CO₂e has already incorporated its stated climate-equivalent basis. Those are different calculation paths.

The general method chapter used here explains activity multiplied by an appropriate factor; its existence does not supply a numerical coefficient for every source. For a real calculation, preserve the actual factor table, row, geography and version. The numbers in the worked example below are explicitly fictional teaching values.

Calculate gas masses and convert to CO2e

When factors return individual gases, calculate each gas mass first. Convert grams to kilograms where required, then multiply each mass by its selected GWP to express it on a common CO₂e basis. Retain the assessment and time-horizon basis so that the conversion can be reproduced. Do not add unlike gas masses and call the sum CO₂e.

A factor already expressed as CO₂e follows the other path. Multiplying the activity by that factor gives CO₂e directly. Another GWP multiplier would repeat a conversion that is already present. Keep that factor’s documented gas coverage and GWP basis with the result; a combined coefficient does not remove the need to know what it includes.

Gas-specific masses need a GWP conversion; an already-CO₂e factor does not need another GWP multiplier.
Read the factor output basis before applying GWP.
Diagram text description

For a gas-specific factor, calculate each gas mass in compatible mass units and apply the selected GWP once. For a factor already expressed as CO₂e, retain that output without another GWP multiplier. Review source results, add compatible kilograms of CO₂e and divide by 1,000 for tonnes.

For a gas-specific line, the dimensional sequence is activity × gas mass per activity unit = gas mass, followed by gas mass × GWP = CO₂e mass. For an already-CO₂e line, it is activity × CO₂e mass per activity unit = CO₂e mass. Both paths must reach compatible output units before aggregation.

Review the source results, sum kilograms of CO₂e and divide by 1,000 to report tonnes. Keep useful calculation precision until the final presentation rather than rounding small gas contributions away. If two factor sets use different GWP bases or emissions boundaries, resolve that mismatch before combining them into an apparently consistent company total.

Walk a fictional multi-source example

Fictional worked example: Alder Works’ controlled workshop sources cover calendar year 2025. All activities, coefficients and record IDs are invented. R-X is a fictional refrigerant used only for this exercise. These numbers are not government factors, IPCC GWP values or a real company footprint. Assume all four direct lines have the stated boundaries and source evidence.

For arithmetic only, use CO₂ GWP = 1 and deliberately hypothetical 100-year multipliers of CH₄ = 20, N₂O = 200 and R-X = 1,000. Boiler teaching factors are 2.0 kg CO₂/L, 1 g CH₄/L and 0.1 g N₂O/L. The van’s invented combined factor is 2.5 kg CO₂e/L and is assumed to cover its relevant direct gases on the same basis. The process factor is an invented 0.2 kg CO₂ per production unit.

Fictional source and inputGas calculation or factor operationCompatible direct result
B-01 boiler: 1,000 L burnedCO₂: 2,000 kg; CH₄: 1,000 g = 1 kg; N₂O: 100 g = 0.1 kg. CO₂e = 2,000 × 1 + 1 × 20 + 0.1 × 2002,040 kg CO₂e = 2.040 t
V-01 van: 500 L used500 × 2.5 kg CO₂e/L; no further GWP multiplier1,250 kg CO₂e = 1.250 t
C-01 cooling unit: 2 kg R-X released2 kg × hypothetical GWP 1,000; purchase quantity is not the input2,000 kg CO₂e = 2.000 t
P-01 process: 50 production units50 × 0.2 kg CO₂/unit × GWP 110 kg CO₂e = 0.010 t
Four-source total2,040 + 1,250 + 2,000 + 10 = 5,300 kg CO₂e5.300 t CO₂e
Separate electricity check: 1,000 kWh purchased1,000 × invented 0.4 kg CO₂e/kWh = 400 kg CO₂e0.400 t on the separate Scope 2 account, excluded from 5.300 t

Table 2, shown one row at a time. Every field is retained.

Row 1

Fictional source and input
B-01 boiler: 1,000 L burned
Gas calculation or factor operation
CO₂: 2,000 kg; CH₄: 1,000 g = 1 kg; N₂O: 100 g = 0.1 kg. CO₂e = 2,000 × 1 + 1 × 20 + 0.1 × 200
Compatible direct result
2,040 kg CO₂e = 2.040 t

Row 2

Fictional source and input
V-01 van: 500 L used
Gas calculation or factor operation
500 × 2.5 kg CO₂e/L; no further GWP multiplier
Compatible direct result
1,250 kg CO₂e = 1.250 t

Row 3

Fictional source and input
C-01 cooling unit: 2 kg R-X released
Gas calculation or factor operation
2 kg × hypothetical GWP 1,000; purchase quantity is not the input
Compatible direct result
2,000 kg CO₂e = 2.000 t

Row 4

Fictional source and input
P-01 process: 50 production units
Gas calculation or factor operation
50 × 0.2 kg CO₂/unit × GWP 1
Compatible direct result
10 kg CO₂e = 0.010 t

Row 5

Fictional source and input
Four-source total
Gas calculation or factor operation
2,040 + 1,250 + 2,000 + 10 = 5,300 kg CO₂e
Compatible direct result
5.300 t CO₂e

Row 6

Fictional source and input
Separate electricity check: 1,000 kWh purchased
Gas calculation or factor operation
1,000 × invented 0.4 kg CO₂e/kWh = 400 kg CO₂e
Compatible direct result
0.400 t on the separate Scope 2 account, excluded from 5.300 t

Valid control: converting the boiler’s 100 g N₂O to 0.1 kg before multiplying by 200 gives 20 kg CO₂e. Invalid controls remain unresolved: litres paired with a per-kilogram factor need a supported conversion; a blank fuel quantity is not zero; and a 5 kg refrigerant purchase cannot replace the supported 2 kg release. Applying CH₄’s multiplier to the van’s already-CO₂e result would also be wrong.

The boiler contributes 2.040 t, the van 1.250 t, the cooling release 2.000 t and the process 0.010 t. Their sum is 5.300 t for these four fictional direct sources only. Grams became kilograms before GWP, and kilograms of CO₂e became tonnes once. Adding the electricity check would change the scope boundary; calculating the van again by distance would duplicate its activity rather than improve the total.

Keep direct and indirect sources apart

Keep the direct result attached to its physical boundary. Fuel burned in a controlled boiler or vehicle is a direct combustion activity under the stated organisational approach. The electricity bought to run equipment is acquired energy, even though its use occurs at the same site. Its generation emissions are accounted for separately in Scope 2.

Upstream fuel extraction, processing and transport are also different activities from burning that fuel at the workshop. A life-cycle fuel coefficient may include those upstream stages. Applying it indiscriminately to the direct line can import emissions outside that line’s boundary. Preserve the factor’s components or select an appropriate direct-combustion factor, then assess relevant upstream activity in Scope 3.

Three rows distinguish controlled fuel combustion in Scope 1, purchased electricity in Scope 2 and upstream fuel production in Scope 3.
Keep direct fuel use, purchased electricity and upstream activity separate.
Diagram text description

Controlled fuel combustion belongs in the direct Scope 1 calculation under the stated boundary. Purchased electricity is accounted for separately in Scope 2. Upstream fuel extraction and production need their relevant Scope 3 treatment rather than being added again to the site combustion line.

For the worked case, the purchased electricity calculation is shown as an exclusion control so the reader can see where it goes. It is not silently ignored, and it is not part of the 5.300 t Scope 1 total. Nor is that four-source total presented as a complete organisational footprint.

Use separate scope and boundary fields in the record. They help prevent an electricity invoice, direct fuel line and upstream estimate from being added together merely because all three have been converted to tonnes of CO₂e.

Run completeness and uncertainty checks

A total can be mathematically correct and still omit a source, include the wrong period or repeat the same activity. Check the calculation against the physical source register and evidence, not only against the spreadsheet’s addition formula. Distinguish a confirmed zero activity from an empty field.

  • Reconcile included sites and assets with the company boundary and identify any source awaiting assessment.
  • Match activity dates and allocation periods to the reporting year.
  • Check denominator units, gram-to-kilogram conversions and the single conversion to tonnes.
  • Confirm source-specific factor versions, geography, GWP basis and direct-emissions coverage.
  • Link duplicate invoices, meter exports or service sheets to one source activity rather than separate emissions lines.

For each missing site, period mismatch, unit issue, old factor or duplicate, record the affected source and its consequence. The facilities team may resolve a meter period; procurement may obtain the factor evidence; the inventory owner decides how an unresolved gap affects the provisional total. A precise total should not hide an unquantified source.

When methods or factors change, explain whether the difference reflects activity, boundary or calculation basis. Retain the earlier version and consider the effect on comparability. The method chapter stresses consistent time series; switching inputs without documenting the reason can make a reported trend difficult to interpret.

Make the calculation reproducible

Use one reconstruction record for each source result. The template below supplies the fields to complete and a filled fictional boiler example. Keep the underlying files accessible by their references; the table is an index to evidence, not a substitute for it. Duplicate the record for each source and preserve its version.

FieldRecord for each sourceFilled fictional B-01 example
Source and equipment IDStable physical source or calculation-account identifierAlder Works boiler B-01
Entity, boundary and periodReporting entity, control basis, site and activity datesWorkshop operational control, calendar year 2025
Activity evidence and unitOriginal file, record version, quantity and unitFuel reconciliation FR-25-v1, 1,000 L burned
Method and factor referenceMethod, publisher or teaching status, table/row, version and geographyFictional factors F-B-v1; no real geography or published rate claimed
Gas and GWP basisGas-specific or already-CO₂e output; selected assessment and horizonCO₂, CH₄, N₂O separately; hypothetical 100-year multipliers 1, 20, 200
Conversion and expressionOriginal units, each conversion and reproducible operationCH₄ 1,000 g → 1 kg; N₂O 100 g → 0.1 kg; gas masses × respective multipliers
Result and scopeCompatible mass, presentation unit and accounting scope2,040 kg CO₂e = 2.040 t, Scope 1
Reviewer and decisionNamed reviewer, date, version and dispositionFictional inventory reviewer Mira Chen; draft held pending activity check
Open uncertainty and ownerMissing evidence, consequence and person responsibleDecember closing tank reading unconfirmed; facilities owner to verify FR-25-v1

Table 3, shown one row at a time. Every field is retained.

Row 1

Field
Source and equipment ID
Record for each source
Stable physical source or calculation-account identifier
Filled fictional B-01 example
Alder Works boiler B-01

Row 2

Field
Entity, boundary and period
Record for each source
Reporting entity, control basis, site and activity dates
Filled fictional B-01 example
Workshop operational control, calendar year 2025

Row 3

Field
Activity evidence and unit
Record for each source
Original file, record version, quantity and unit
Filled fictional B-01 example
Fuel reconciliation FR-25-v1, 1,000 L burned

Row 4

Field
Method and factor reference
Record for each source
Method, publisher or teaching status, table/row, version and geography
Filled fictional B-01 example
Fictional factors F-B-v1; no real geography or published rate claimed

Row 5

Field
Gas and GWP basis
Record for each source
Gas-specific or already-CO₂e output; selected assessment and horizon
Filled fictional B-01 example
CO₂, CH₄, N₂O separately; hypothetical 100-year multipliers 1, 20, 200

Row 6

Field
Conversion and expression
Record for each source
Original units, each conversion and reproducible operation
Filled fictional B-01 example
CH₄ 1,000 g → 1 kg; N₂O 100 g → 0.1 kg; gas masses × respective multipliers

Row 7

Field
Result and scope
Record for each source
Compatible mass, presentation unit and accounting scope
Filled fictional B-01 example
2,040 kg CO₂e = 2.040 t, Scope 1

Row 8

Field
Reviewer and decision
Record for each source
Named reviewer, date, version and disposition
Filled fictional B-01 example
Fictional inventory reviewer Mira Chen; draft held pending activity check

Row 9

Field
Open uncertainty and owner
Record for each source
Missing evidence, consequence and person responsible
Filled fictional B-01 example
December closing tank reading unconfirmed; facilities owner to verify FR-25-v1

The example arithmetic is reproducible under its assumptions, while its fictional reviewer decision remains open. If the closing tank reading changes, revise the activity version and recalculate the affected source rather than editing the final total alone. A real record must replace the teaching factors and hypothetical GWPs with supported sources and the applicable reporting basis.

Retain the decision that follows a review, including any exception carried forward. This allows another preparer to distinguish a draft calculation from the version actually used in a report.

Keep each calculation connected to its evidence

A useful calculation trail joins source records, units, factors and exceptions without erasing their different roles. Give each evidence item a stable reference and identify who can supply or correct it. An invoice establishes a transaction, a meter supports activity, a factor describes an emissions relationship and a reviewer records the decision about their use.

For the fictional boiler, the facilities owner holds the tank readings and the inventory owner controls the factor and GWP references. The reviewer’s open question about December belongs beside B-01 and its current result. A new fuel file should identify the version it replaces so the effect on the calculation can be followed.

Keep confirmed inputs and unresolved items visible together. If a source is estimated, label the method and assumption. If a required factor is missing, state the consequence for that line instead of allowing a blank cell to disappear from the total. Apply the same discipline to vehicle activity, refrigerant release evidence and process data.

This organisation helps the next person choose the right task: obtain evidence, correct a unit, resolve a boundary or review a completed line. It also makes a recalculation easier to explain because the changed input remains connected to the affected source.

Use dedicated methods where depth is needed

Use the source-by-source method to decide where more depth is needed. A boiler or fleet calculation requires the appropriate fuel and application method. A fugitive source needs a supported gas-release estimate before GWP conversion. A chemical process needs its own material or production basis. A disputed lease or operating arrangement belongs in the organisational-boundary assessment first.

The next useful step is to fill the source register and reconstruction records with actual evidence. Replace every teaching coefficient and hypothetical multiplier before applying the worked arithmetic to a real inventory. Keep purchased energy and upstream activity on their separate accounts, and retain the explanation for missing sources or provisional estimates.

Once the sources, factors and units are established, the calculation should be reproducible from the record rather than dependent on the person who built the spreadsheet. A management plan can then assign recurring evidence collection, review and change controls. The final total is useful when its boundary, source contributions and remaining uncertainties can all be explained.