A woman reviews printed records at a desk beside a laptop, with industrial equipment visible through the window.
Connect the inventory decisions with the records behind them.
Diagram text description

A synthetic editorial scene shows a woman reviewing printed documents beside a laptop in an office overlooking industrial equipment. No legible activity quantity, factor value, customer identifier, inventory total or assurance result is visible.

A Scope 1 total can look convincing while answering the wrong question. A boiler may be physically on your site but operated under another party’s authority. A fuel invoice may describe deliveries rather than consumption. A spreadsheet may calculate perfectly while leaving out an entire source family. Understanding Scope 1 emissions under the GHG Protocol means connecting those decisions before presenting a company result.

Start with the corporate inventory framework, choose the organizational boundary, classify the physical releases, and then select suitable methods and evidence. Calculation tools can help with the arithmetic; using one does not certify the inventory. This guide separates those responsibilities, compares owned, leased and shared operations under a stated control policy, and follows a fictional source record into a provisional reporting line. The useful outcome is a result whose boundary, inputs and remaining questions another person can reconstruct. That matters whether you are collecting records for a first inventory or investigating why this year’s number differs from last year’s. A change in ownership, method or evidence can change the reported result without representing a change in physical emissions.

Boundary and source register connect to method and gas results, then reviewer decision and reported line.
A reported source needs a connected chain of decisions and evidence.
Diagram text description

Define the boundary and identify the direct source first. Connect the source record to its method, factor and gas result. Retain the reviewer decision and any unresolved limitation before the reported inventory line; a documented chain alone is not assurance.

Start with the corporate inventory framework

The GHG Protocol Corporate Accounting and Reporting Standard provides the framework for a corporate greenhouse gas inventory. It addresses which operations are consolidated, how direct and indirect emissions are separated, and how the inventory is accounted for and reported. It is more than a list of formulas. A preparer needs an inventory policy as well as a calculation file, because the same physical activity can sit in different accounts when the reporting relationship changes.

Keep four responsibilities separate. The framework establishes the accounting structure. A source method explains how to quantify a physical mechanism. Activity records and factors supply the inputs. Review establishes what has been checked and what remains uncertain. A result can have strong evidence at one layer and weak evidence at another: a meter reading does not establish operating control, while a signed boundary policy does not establish how much fuel was burned.

The Corporate Standard publisher page also distinguishes corporate inventories from quantifying offset-project reductions. Do not subtract a credit purchase from a direct-source record to make its physical release disappear. Similarly, an organized inventory is not a verification opinion. Establish the intended reporting audience and any applicable programme requirements at the outset, then record the framework and guidance versions used. That makes later questions about scope or methodology answerable without treating a familiar standard name as a universal certificate.

Choose who belongs in the inventory

An organizational boundary identifies the operations consolidated into the reporting company’s inventory. Choose the approach before deciding which facilities produce the most convenient total. The Corporate Standard distinguishes equity share from control approaches, with control assessed financially or operationally. Apply the chosen policy consistently across subsidiaries and joint operations; do not switch lenses for individual sources merely because another treatment gives a smaller figure.

Equity share follows economic interest. Financial control concerns the relevant financial-policy and benefit relationship, with specific treatment for joint financial control. Operational control asks who has authority to introduce and implement operating policies. These are different questions about the same operation. The revised Corporate Standard, chapter 3, explains why shared operations can enter the boundary differently under the selected approach.

Three independent rows compare equity share, financial control and operational control.
Choose one consolidation policy and apply its test consistently.
Diagram text description

Equity share asks about economic interest. Financial control asks about the relevant financial control relationship. Operational control asks who can introduce and implement operating policies. Evaluate the same operation under the selected approach rather than mixing the most convenient answer from each.

In practice, assemble an operations register with the reporting entities, sites, ownership interests, operating arrangements and effective dates. Link each disputed operation to a short decision record. Ask the relevant finance, legal and operations owners to identify the document and actual responsibility supporting the chosen classification. A percentage in an ownership register is useful evidence for one question; it cannot answer every control question.

Record the policy at company level and carry it into site instructions. Otherwise, one facility may report a shared plant in full while another reports only a share of a comparable operation. The resulting total would conceal inconsistent consolidation rather than represent a coherent company boundary.

Draw the operational boundary

After determining which operations belong in the inventory, draw the operational boundary: identify the physical activities and separate direct releases from indirect emissions. Scope 1 covers direct greenhouse gas emissions from sources owned or controlled by the reporting entity within its accounting boundary. Purchased energy and other value-chain activities require their own treatment. Location alone is not enough: several organizations can use one building while controlling different sources.

Physical activityClassification under the stated boundaryRecord that supports the decision
Fuel burns in a boiler operated within the company boundaryDirect combustion in Scope 1Boiler identity, operating responsibility and fuel-consumption record
Electricity is purchased for that operationPurchased-energy emissions in Scope 2Electricity supply and consumption records
A supplier extracts and produces the boiler fuelOther indirect activity in Scope 3Supplier/activity relationship and the appropriate value-chain assessment

Table 1, shown one row at a time. Every field is retained.

Row 1

Physical activity
Fuel burns in a boiler operated within the company boundary
Classification under the stated boundary
Direct combustion in Scope 1
Record that supports the decision
Boiler identity, operating responsibility and fuel-consumption record

Row 2

Physical activity
Electricity is purchased for that operation
Classification under the stated boundary
Purchased-energy emissions in Scope 2
Record that supports the decision
Electricity supply and consumption records

Row 3

Physical activity
A supplier extracts and produces the boiler fuel
Classification under the stated boundary
Other indirect activity in Scope 3
Record that supports the decision
Supplier/activity relationship and the appropriate value-chain assessment

The fuel invoice can relate to both a controlled combustion activity and an upstream supply chain, but those are different physical activities. Do not add an upstream life-cycle factor to the boiler’s direct-combustion result and label the combined figure Scope 1. Purchased electricity also stays outside that boiler line even when its meter is beside the boiler.

The GHG Protocol calculation-tools FAQ explains the direct/indirect distinction. Use the relevant scope guidance and reporting requirements to complete the indirect accounts; the classification here does not settle every Scope 2 or Scope 3 reporting obligation. When control changes, revisit the source relationship and its effective date rather than simply copying last year’s scope label.

List every direct-source family

Build a direct-source register before selecting calculators. A single site can contain combustion equipment, vehicles, refrigerant systems and chemical processes, each with a different route to emissions. Give every identified source a stable ID, physical location, responsible owner and reporting period. Screening is a search for sources and supported absences, not a request for whichever invoices happen to be easiest to find.

  1. Screen stationary combustion. Inspect boilers, furnaces, backup generators and other fixed fuel-burning equipment. Connect each item to its fuel type and consumption evidence, including tanks or meters shared between equipment.
  2. Screen mobile combustion. Compare the vehicle and mobile-equipment register with fuel records and operating responsibility. Distinguish company-controlled combustion from a third party’s transport service before choosing fuel or distance-based inputs.
  3. Screen process releases. Ask production and engineering staff whether a chemical transformation releases greenhouse gases independently of fuel combustion. Materials, production quantities or direct measurements may be relevant; an energy bill will not describe every process.
  4. Screen fugitive losses. Review refrigeration, air conditioning and other gas-containing systems, including service movements, recovery and known losses. Purchased refrigerant is not automatically released refrigerant.

An empty family needs an explanation. Check equipment lists for stationary sources, fleet records for mobile sources, maintenance records for fugitive systems and production descriptions for process sources. Record who checked and why the family was absent, rather than leaving a blank that could mean “not applicable,” “no data” or “not investigated.”

Reconcile the register with the people who operate the site. A standby generator can be missed by an annual energy summary, and a small service account can identify a refrigerant system missing from a facilities spreadsheet. Keep unresolved sources visible with an owner and next evidence request. Missing data should trigger an estimation or evidence decision, not silent deletion.

Treat leased assets and joint operations as boundary decisions

The following comparison is fictional. Larch Engineering uses operational control consistently for its corporate inventory. For these cases, assume the contract and actual operating arrangements establish clearly whether Larch has full authority to introduce and implement operating policies. The table addresses direct releases from the equipment; any purchased electricity associated with an included operation remains a separate Scope 2 activity.

Ownership, payment and authority are separate facts. A leased item is not automatically outside the boundary, and holding an economic interest in a joint operation does not by itself settle operational control. Use the agreement together with evidence of actual responsibilities. For complex leases, consult the relevant accounting and current reporting guidance rather than translating an old lease label into an automatic emissions answer.

An operational-control policy tests full authority over operating policies, leading to direct-release inclusion or assessment of another inventory route.
For this operational-control example, test operating authority.
Diagram text description

This gate applies only to the fictional example using operational control. Contract terms and actual authority determine whether the company can introduce and implement operating policies. A yes leads to inclusion of the operation’s direct releases; a no requires assessment of the relevant other inventory route, not deletion of the activity.

Fictional operationExplicit authority assumptionTreatment under Larch’s operational-control policyEvidence supporting that decision
Owned boiler BO-07Larch sets and implements the operating policiesInclude 100% of its direct releases in Scope 1Asset register, operating responsibility and site policy
Leased generator LG-02The lease gives Larch operating-policy authority, which it exercisesInclude 100% of its direct releases in Scope 1Executed lease, operating clauses and responsibility records
Joint workshop JW-04; Larch economic interest 40%The joint-operation agreement gives Larch operating-policy authorityInclude 100% of its direct releases under this policy, rather than applying 40%Joint-operation agreement and evidence of who implements operating policies
Changed JW-04 arrangementAn amendment transfers operating-policy authority to the partner; Larch retains its 40% interestAfter the effective change, exclude these releases from Larch’s Scope 1 and assess the relevant indirect treatmentDated amendment, handover and actual operating responsibility after the change

Table 2, shown one row at a time. Every field is retained.

Row 1

Fictional operation
Owned boiler BO-07
Explicit authority assumption
Larch sets and implements the operating policies
Treatment under Larch’s operational-control policy
Include 100% of its direct releases in Scope 1
Evidence supporting that decision
Asset register, operating responsibility and site policy

Row 2

Fictional operation
Leased generator LG-02
Explicit authority assumption
The lease gives Larch operating-policy authority, which it exercises
Treatment under Larch’s operational-control policy
Include 100% of its direct releases in Scope 1
Evidence supporting that decision
Executed lease, operating clauses and responsibility records

Row 3

Fictional operation
Joint workshop JW-04; Larch economic interest 40%
Explicit authority assumption
The joint-operation agreement gives Larch operating-policy authority
Treatment under Larch’s operational-control policy
Include 100% of its direct releases under this policy, rather than applying 40%
Evidence supporting that decision
Joint-operation agreement and evidence of who implements operating policies

Row 4

Fictional operation
Changed JW-04 arrangement
Explicit authority assumption
An amendment transfers operating-policy authority to the partner; Larch retains its 40% interest
Treatment under Larch’s operational-control policy
After the effective change, exclude these releases from Larch’s Scope 1 and assess the relevant indirect treatment
Evidence supporting that decision
Dated amendment, handover and actual operating responsibility after the change

The changed case isolates the boundary condition: authority changes while economic interest does not. It therefore changes the operational-control answer. Preserve the effective date and segregate activity on each side of the handover. Do not remove the whole year merely because the year-end operator is different.

Under an equity-share policy, the unchanged economic interest would instead be relevant to the share consolidated. That is a comparison of policies, not permission to blend them in one total. In a real disputed case, leave the classification open until the specific contract and control evidence support it.

Collect records that represent actual activity

Collect records that represent the physical activity in the chosen reporting period. Fuel deliveries, tank levels and fuel burned are related but different quantities. A refrigerant invoice establishes a purchase, not necessarily a release. A production quantity describes an output, but may need composition or process information before it represents an emissions-generating reaction. Preserve original records before converting their units or distributing quantities between sources.

For each source, retain its ID, activity description, original quantity and unit, start and end dates, evidence location and responsible data owner. Identify the gas or gas mixture where relevant. Keep the original document and the calculation-ready value linked so a reviewer can trace a spreadsheet cell back to a meter, log, service record or production report. Record any estimate separately from a measured input.

Timing deserves its own check. An invoice dated in January can cover December consumption, and a delivery near year-end can remain in storage. Reconcile the relevant opening stock, receipts, transfers and closing stock where the method requires it. For refrigerants, inspect installation, servicing, recovery and disposal records rather than equating every top-up with a verified atmospheric loss.

If records disagree, describe the disagreement in the source register. State which value is provisional, why it was selected and what evidence could change it. A visible exception is more useful than an unexplained adjustment buried inside a formula. Ask for the missing record from its owner before treating a reconciled-looking total as a completed investigation.

Use calculation tools without confusing them with the standard

A calculation tool helps implement a method; it does not choose the entire inventory policy for you. The GHG Protocol FAQ describes its tools as complementary and says their use is not mandatory. That leaves a preparer responsible for selecting a suitable method, checking the inputs and retaining the calculation trail. A familiar spreadsheet filename is not evidence that the current source, factor or reporting period fits.

LayerQuestion it answersWhat it cannot establish by itself
Corporate accounting frameworkWhich operations, scopes and reporting principles apply?The measured activity at a particular source
Selected source methodHow will this physical release be quantified?Whether the operation belongs in the company boundary
Calculation tool or worksheetHow are the selected inputs processed?Completeness, appropriate factors or assurance merely from use
Assurance engagement and conclusionWhat was independently assessed under the engagement’s criteria and scope?A wider conclusion beyond the work actually performed

Table 3, shown one row at a time. Every field is retained.

Row 1

Layer
Corporate accounting framework
Question it answers
Which operations, scopes and reporting principles apply?
What it cannot establish by itself
The measured activity at a particular source

Row 2

Layer
Selected source method
Question it answers
How will this physical release be quantified?
What it cannot establish by itself
Whether the operation belongs in the company boundary

Row 3

Layer
Calculation tool or worksheet
Question it answers
How are the selected inputs processed?
What it cannot establish by itself
Completeness, appropriate factors or assurance merely from use

Row 4

Layer
Assurance engagement and conclusion
Question it answers
What was independently assessed under the engagement’s criteria and scope?
What it cannot establish by itself
A wider conclusion beyond the work actually performed

Before using a tool, inspect its source coverage, required inputs, formula basis and factor references. Confirm whether it returns individual gas masses or CO2e, whether its units match the records, and whether default factors remain suitable for the geography and period. Preserve the version used. Updating a workbook without retaining the previous version can make last year’s result difficult to reproduce.

A custom worksheet can still contain poor assumptions, just as an official tool can be fed unsuitable data. Review the actual method and evidence rather than treating either origin as a guarantee. If a tool cannot represent a source reliably, document the limitation and choose a supported approach; do not force the source into the closest-looking input field.

Select methods and factors that fit each source

Select methods by the physical mechanism. Stationary combustion may use fuel consumed and compatible fuel factors. Mobile combustion may use fuel records or a supported activity-based estimate. Fugitive refrigerant work needs a defensible released-mass estimate or another suitable method, with gas identity preserved. Process emissions can require material composition, production or measurements describing the chemical transformation. These are different measurement problems, even when their final outputs share the same unit.

For each selected factor, record the publication or provider, version, applicable year, geography, source or technology, gas coverage and denominator unit. Check the emissions boundary as well: a life-cycle coefficient is not interchangeable with a direct-combustion coefficient. A unit match is necessary but insufficient. Litres of different fuels can have different characteristics, and an average factor may not represent a specific process or operating condition.

Check what the output means before adding a GWP multiplier. A coefficient expressed as kilograms of a named gas per unit of activity returns that gas mass. A coefficient already expressed as kilograms of CO2e per unit includes an equivalence basis that must be understood and retained. Do not convert the latter a second time.

Document why the factor is appropriate and what remains uncertain. If composition is unknown or a factor applies to a different technology, explain the limitation and obtain better evidence or justify the estimate. The next improvement should address that particular weakness rather than merely adding more decimal places to the result.

Convert and aggregate without counting twice

Keep source calculations separate until their boundaries, periods and output units are compatible. For a method returning individual gas masses, apply the documented global warming potential basis to the appropriate masses and derive CO2e. For a factor already returning CO2e, preserve that result without another gas-specific GWP multiplier. These are alternative conversion paths, not two successive multipliers for every source.

Reconcile the source register against the calculation file before summing. Each source needs one clear contribution for the relevant activity and period. A boiler’s metered fuel and the invoice used to check that fuel must not become two emissions lines for the same consumption. Where equipment shares a tank, retain the allocation basis and ensure the allocated quantities reconcile to the supported whole. Keep intersite transfers from becoming both consumption at the sending site and consumption at the receiving site.

Gas-specific mass uses GWP once; already-CO₂e output uses no further GWP. Compatible reviewed results are summed.
Convert the gas basis once, then reconcile compatible results.
Diagram text description

When the method returns individual gas masses, use compatible mass units and the selected GWP basis once. An already-CO₂e coefficient has that conversion in its output, so do not multiply by a gas GWP again. Reconcile source IDs, scope and period before summing compatible results and converting kilograms to tonnes.

Use a common aggregation unit and make the final conversion visible. There are 1,000 kilograms in a tonne; converting a kilogram total to tonnes requires division by 1,000. Do not add kilograms of one gas directly to tonnes of CO2e or combine differently defined reporting periods without reconciliation.

Keep gross direct-source results distinct from purchased energy, upstream supply-chain activity and offset claims. A reduction initiative can be described separately without changing the underlying source record. The company total should retain enough detail to show which source results were included, which were held provisional, and which belong in another account. A smooth-looking final number cannot substitute for those checks.

Review completeness and changes over time

Compare the operations register, source register and calculated totals at each reporting cycle. Investigate a site with no source rows, an active source with no activity or an unexplained fall to zero. Keep exclusions visible with reasons and evidence. Review evidence versions, changed factors and the inventory’s base-year and recalculation policy before calling a year-on-year difference an emissions reduction.

Suppose a business acquires a workshop, corrects a fuel-unit error and replaces an estimated refrigerant input with service evidence in the same year. Those changes have different meanings from using less fuel at an unchanged operation. Assess their effect under the chosen reporting framework and recalculation policy, document the treatment and preserve both the original and revised records. Do not present every movement in the reported total as physical improvement.

Ask source owners to explain unusual changes using operational records: equipment additions, shutdowns, production changes, fuel substitutions or maintenance events. Reconcile the explanation with the quantity and period involved. If an exclusion or unresolved estimate could affect interpretation, disclose it rather than relying on a small-looking contribution to justify silence.

Version control should preserve the boundary decision, activity evidence, method, factor and reviewer action together. A reviewer needs to know which combination produced the report, not simply which workbook was saved most recently. Close an issue only when its evidence and decision are recorded; carry unresolved items into the next reporting cycle with named responsibility. This makes improvement work specific and keeps comparisons from drifting as records are replaced.

Follow a fictional source-to-report trail

This filled source-to-report trail is entirely fictional. Larch Engineering, source BO-07, all record identifiers, activity quantities and the coefficient below are invented for teaching. The scenario covers calendar 2025 under Larch’s stated operational-control policy. Its coefficient already returns CO2e and is not a published fuel factor or a recommended value for a real inventory.

Trail stageFilled fictional entryEvidence or remaining limitation
Accounting framework and boundaryCorporate inventory; operational control; BO-07 included as Larch-operated stationary combustionDecision BD-07 links the boiler register and operating authority
Selected methodFuel activity multiplied by an already-CO2e direct-emissions coefficientMethod note MN-07; excludes upstream fuel production
Activity evidenceProvisional 420 L of teaching fuel F-Blue consumed during calendar 2025Meter log ML-07 and stock reconciliation SR-07; last 30 L transfer unresolved
Factor basisTEACH-FB-v1: invented 2.4 kg CO2e per litre of F-BlueTeaching coefficient only; no additional GWP multiplier
Calculation and units420 L × 2.4 kg CO2e/L = 1,008 kg CO2e = 1.008 t CO2eArithmetic is reproducible; input classification remains provisional
Source-to-report linkInventory line INV-BO07-2025; provisional contribution 1.008 t CO2eLinks BD-07, MN-07, ML-07, SR-07 and TEACH-FB-v1
Unresolved reviewer questionWere the last 30 L consumed by BO-07 or transferred to another site?Facilities owner must supply the transfer/consumption record; reviewer has not closed the issue

Table 4, shown one row at a time. Every field is retained.

Row 1

Trail stage
Accounting framework and boundary
Filled fictional entry
Corporate inventory; operational control; BO-07 included as Larch-operated stationary combustion
Evidence or remaining limitation
Decision BD-07 links the boiler register and operating authority

Row 2

Trail stage
Selected method
Filled fictional entry
Fuel activity multiplied by an already-CO2e direct-emissions coefficient
Evidence or remaining limitation
Method note MN-07; excludes upstream fuel production

Row 3

Trail stage
Activity evidence
Filled fictional entry
Provisional 420 L of teaching fuel F-Blue consumed during calendar 2025
Evidence or remaining limitation
Meter log ML-07 and stock reconciliation SR-07; last 30 L transfer unresolved

Row 4

Trail stage
Factor basis
Filled fictional entry
TEACH-FB-v1: invented 2.4 kg CO2e per litre of F-Blue
Evidence or remaining limitation
Teaching coefficient only; no additional GWP multiplier

Row 5

Trail stage
Calculation and units
Filled fictional entry
420 L × 2.4 kg CO2e/L = 1,008 kg CO2e = 1.008 t CO2e
Evidence or remaining limitation
Arithmetic is reproducible; input classification remains provisional

Row 6

Trail stage
Source-to-report link
Filled fictional entry
Inventory line INV-BO07-2025; provisional contribution 1.008 t CO2e
Evidence or remaining limitation
Links BD-07, MN-07, ML-07, SR-07 and TEACH-FB-v1

Row 7

Trail stage
Unresolved reviewer question
Filled fictional entry
Were the last 30 L consumed by BO-07 or transferred to another site?
Evidence or remaining limitation
Facilities owner must supply the transfer/consumption record; reviewer has not closed the issue

BO-07 connects the reporting period, original litre unit, invented fuel identity and factor basis to specific evidence and an open exception. If the last 30 L belong elsewhere, the provisional activity and report line must change; the tidy arithmetic does not decide that question. Retain the current result as provisional while requesting the transfer record. Do not count the same fuel at both sites to avoid leaving a visible gap.

This is a filled record with a live review limit, not an assurance opinion or proof of conformance. Even resolving the transfer would not establish that every other corporate source was included or that all applicable reporting requirements were met. A real inventory would also need a suitable sourced coefficient and its actual applicability checked. The example shows how to connect the layers and expose what the reviewer still cannot conclude.

Keep the evidence connected to its decisions

Keep the evidence trail accessible to the people who must make and review the inventory decisions. The useful task is to connect source identity, boundary, activity, method, factor version, calculation and outstanding questions. Record organization can support that task, but it cannot replace source-owner judgment, establish an assurance conclusion or guarantee that an inventory meets every reporting requirement.

Assign responsibilities explicitly. Operations can explain equipment and physical activity; finance and contract owners can provide ownership, lease and consolidation evidence; the preparer can document the selected method; the reviewer can challenge the evidence and the reported treatment. One person may hold several roles in a small company, but the questions remain distinct. Mark a missing decision as open instead of assuming that a completed field represents approval.

Use a consistent index that points from the report line back to the calculation and original evidence. Preserve access to prior versions when a quantity, factor or boundary decision changes. Keep an issue log showing the question, owner, evidence requested and current treatment, including whether the result is provisional.

When choosing a record-management approach, test whether a colleague can follow one disputed source without verbal explanation. If the colleague cannot identify the activity period or why a factor was selected, improve that connection first. A polished dashboard is useful only when the records and decisions behind its figures remain understandable.

Move from framework to category-specific work

A defensible Scope 1 inventory begins with a coherent boundary and ends with a result connected to evidence. The framework, source classification, quantification method, calculation support and review each answer different questions. Resolve them in that order without letting a tool name or an organized folder stand in for the missing decision.

Choose the next task from the gap you actually found. For a disputed lease or joint operation, obtain the contract and operating-authority evidence. For combustion, reconcile fuel activity and a suitable factor. For fugitive gases, establish gas identity and a defensible release estimate. For a changing inventory, assess comparability and the relevant recalculation treatment.

Before reporting, test one source from its original record through to the final line and then check that the wider source register is complete. State provisional values and unresolved questions clearly. That gives the next preparer or reviewer a practical starting point and keeps an inventory statement proportionate to the work and evidence supporting it.