What Is Included in Scope 2 Emissions? A Boundary Checklist
An illustrative facility energy-management scene, not a real customer operation or measured emissions result.
Diagram text description
What is included in Scope 2 emissions? Start with electricity, steam, heat and cooling that your organisation purchases or otherwise acquires and consumes within its reporting boundary. Scope 2 concerns the emissions from generating that energy. A utility account is useful evidence, but neither an invoice heading nor the physical location of equipment settles the boundary on its own.
This distinction matters at ordinary sites. An office can acquire electricity through a landlord, a factory can buy steam through a pipe, and a building can purchase district cooling without owning a chiller. Meanwhile, fuel burnt in a boiler inside the reporting boundary belongs in direct-emissions assessment, and wider energy-chain impacts require separate value-chain treatment. Putting every energy-related expense into Scope 2 would mix these different activities.
The practical output of this checklist is a source register for one site and reporting period. It records each of the four energy streams, the facts supporting inclusion or exclusion, and any unresolved question. Complete that boundary decision before choosing factors: a well-calculated result cannot compensate for a missing steam connection or an incorrectly classified leased office.
The four purchased-energy forms to check
The four forms are electricity, steam, heat and cooling. Test each form at every site, even when the initial answer appears to be none. Electricity is often easy to find in a bill archive; thermal energy can sit in a facilities contract, service charge or industrial-park agreement instead. Leaving those departments out of the request can leave an otherwise thorough inventory incomplete.
The forms describe acquired energy, not every device that produces a similar service. An electric heater using your acquired electricity does not mean you purchased heat as a second energy stream. A chiller operated within your boundary may consume acquired electricity; purchasing chilled water from a separate district supplier is a different transaction. Identify what actually crosses the relevant reporting boundary rather than classifying the equipment by its name.
Electricity, steam, heat and cooling remain four separate inputs to the same inclusion test. The diagram does not assert that every site purchases all four streams.
Diagram text description
An explicit absent-stream entry is valuable. “No purchased steam; site has no steam connection, confirmed by facilities” tells the next reporting owner more than an empty cell. It also gives a concrete question to revisit if the site changes. A blank does not distinguish absence from an unanswered request.
Purchased electricity is not always just a utility bill
Purchased electricity can reach a facility through a direct utility contract, a landlord recharge or a direct connection to a separate generator. The payment route and the energy route may differ. For example, the utility bill may name the building owner while a tenant consumes an allocated share of the electricity. The tenant's inventory treatment depends on its organisational boundary, not simply whose name appears at the top of the invoice.
Identify the consuming operation first. Which legal entity reports it, and which consolidation approach is applied: equity share, financial control or operational control? Use that approach consistently across the inventory. Do not adopt a different approach for a difficult lease merely because it produces an easier data request or a smaller total.
Then trace the electricity serving that operation. A meter reference, supply agreement and landlord statement can together explain a route that no single document describes. Record whether the quantity is directly metered or allocated and which spaces it represents. A landlord's total building consumption is not automatically the tenant's consumption; an allocation requires an explained basis.
Direct-line electricity needs the same discipline. Equipment on your roof or within an industrial park may belong to another entity. Ask who operates or controls generation, who acquires the output and where it is consumed. The wire's length does not determine the scope. Keep imports, self-generation and exports distinguishable so that an apparently simple net bill does not hide the underlying flows.
District steam, heating and cooling belong on the same checklist
District energy often supplies a usable thermal service rather than fuel for the buyer's own equipment. A steam delivery, hot-water connection or chilled-water service can therefore reveal a Scope 2 source that an electricity-only request misses. Facilities and engineering teams are often better placed than accounts payable to identify the connection and the equipment behind it.
For each thermal stream, obtain a small evidence package:
- The contract or supplier statement naming the delivered energy and the parties to the arrangement.
- The served site, consuming operation and dates covered, including any change of operator during the year.
- The meter or delivery record and its physical unit, with an explanation of estimated or allocated quantities.
- The identity and boundary status of generation, with a contact who can clarify the supply arrangement.
Keep a thermal quantity distinct from a financial charge. Money spent on a service is not itself a measurement of heat or cooling. Steam stated by mass may require additional thermal information for a later calculation. A chilled-water volume also needs an appropriate energy basis; it is not interchangeable with electricity consumption. Record the available unit accurately and mark the conversion requirement instead of silently relabelling it.
Finally, avoid counting the same delivery twice because one document calls it steam and another calls it heating. The register should identify the actual stream and the service it provides. The four-form check ensures completeness; it does not require four positive quantities where only one delivery exists.
The boundary test: who generated and who consumed the energy?
Work through three boundary questions in order. First, does the consuming operation fall within the reporting organisation under its chosen consolidation approach? Second, is the generation a direct source within that boundary or an energy supply from another entity? Third, what energy was acquired and consumed by the included operation during the period? The answers establish a reasoned classification rather than an assumption based on the site's address.
For owned or controlled combustion within the boundary, assess the resulting direct emissions in Scope 1. For energy acquired from outside generation and consumed within the boundary, assess Scope 2. A fuel invoice and a heat invoice can consequently have different treatments even if both ultimately warm the same building. What was bought and who generated the energy are decisive facts.
Generation inside the reporting boundary leads to direct-source assessment. Generation outside it leads to testing acquisition and consumption, rather than automatic Scope 2 inclusion. This initial branch does not resolve the separate electricity attribute-sale exception.
Diagram text description
The generation branch is an initial classification aid, not a complete answer for every electricity arrangement. The Scope 2 Guidance also addresses energy-attribute sales from owned and consumed generation. If certificates or other attributes were transferred, keep that transaction visible and apply the relevant guidance before finalising treatment. Do not infer a zero-emissions claim merely from owning renewable equipment or seeing it on-site.
For a complex site, draw a simple equipment-and-flow map alongside the register. Show the generating entity, the consumer, imports and exports, and the reporting boundary. This is especially useful when a third party operates equipment on the premises or one corporate group supplies several operations. The map explains the relationship; the register records which evidence establishes it.
What stays in Scope 1 instead
Buying a fuel is different from buying the energy generated from it. If a gas boiler is a direct source inside your reporting boundary, its combustion emissions belong in Scope 1 assessment. The heat it produces for your own operation is not an additional purchased-heat Scope 2 entry. The same principle applies to fuel used in an included generator or vehicle.
There can still be a separate acquired-energy input at the same installation. An owned boiler may use grid electricity for pumps or controls. That electricity can enter the electricity register without moving the gas combustion into Scope 2. Keeping separate source references helps prevent one equipment asset from receiving one overly broad scope label.
Apply the boundary consistently to leased equipment too. Ownership is relevant, but the organisation's consolidation approach and actual control arrangements must be understood. A record that says only “rented generator” leaves the classification unfinished. Capture the contractual and operating facts that determine whether it is a direct source within the inventory or a different arrangement requiring further assessment.
What is outside Scope 2 but may still matter
Scope 2 addresses generation of the acquired energy, rather than every impact along the energy supply chain. Upstream fuel extraction and processing are separate from combustion at the electricity or thermal generator. For an ordinary end user, generation associated with purchased-grid transmission and distribution losses is also outside its Scope 2 consumed-energy generation figure and may fall within Scope 3 Category 3.
That exclusion is an accounting separation, not a claim that these activities have no climate impact. Retain their source information for the appropriate assessment. When a supplier provides a life-cycle intensity, establish what it includes before treating the whole value as a Scope 2 generation factor. Otherwise upstream activity can be placed in Scope 2 and then counted again in a separate energy-related Scope 3 calculation.
The Scope 2 boundary contains acquired-energy generation. Upstream fuel production and grid losses in the ordinary end-user case are visibly outside it and remain relevant to separate value-chain assessment.
Diagram text description
The end-user qualification matters. A transmission or distribution operator has different activities and reporting questions from an office buying grid electricity. Do not export an end-user rule unchanged to a network business. The source register should describe the reporting operation so that a later analyst can see why the selected treatment applies.
Value-chain activities are not purchased-energy generation
An indirect activity does not become Scope 2 simply because another company used electricity to perform it. A supplier's manufacturing, outsourced freight, third-party business travel and employee commuting are value-chain activities to assess separately. Your company bought a product or service in those cases, rather than necessarily acquiring the generating energy for consumption in an included operation.
Use the object of the transaction as a diagnostic question. Are you documenting energy supplied to your operation, or an external activity delivered to it? A district-cooling supply and an external logistics service can both support a warehouse, but their relationship to energy consumption is different. The scope decision follows that relationship, not the department that paid the bill.
Keep excluded records traceable to the appropriate inventory work rather than discarding them. A freight record marked “outside Scope 2” is not a completed Scope 3 calculation. Its next owner still needs to determine the relevant activity category, quantity and method. A clear handoff prevents the boundary exercise from becoming a reason to omit an important source altogether.
Borderline examples that change the answer
These illustrative cases show how particular facts resolve the inclusion decision. They contain no measured emissions results. Each assumes the stated reporting period and consolidation approach; changing those facts can change the treatment.
| Case | Established facts | Boundary decision | Evidence still needed |
|---|---|---|---|
| Leased office | Tenant uses operational control, controls the leased operation and acquires grid electricity through a landlord recharge | Include the tenant's acquired and consumed electricity in Scope 2 | Meter or explained tenant allocation, lease and covered period |
| Owned gas boiler | Boiler is a direct combustion source within the reporting boundary; heat serves the same included operation | Assess gas combustion in Scope 1; do not add the self-produced heat as purchased heat in Scope 2 | Fuel quantity and source record; identify any separately acquired auxiliary electricity |
| District cooling | External supplier generates cooling delivered to an operation inside the reporting boundary | Include the acquired cooling stream in Scope 2 | Supply contract, delivered-energy basis and supplier information for the later calculation |
| Purchased CHP steam | Separate supplier operates the combined heat and power plant; buyer acquires steam consumed inside its boundary | Include the acquired steam stream in Scope 2 | Delivered quantity and support for allocation of generator emissions to the steam output |
Table 1, shown one row at a time. Every field is retained.
Row 1
- Case
- Leased office
- Established facts
- Tenant uses operational control, controls the leased operation and acquires grid electricity through a landlord recharge
- Boundary decision
- Include the tenant's acquired and consumed electricity in Scope 2
- Evidence still needed
- Meter or explained tenant allocation, lease and covered period
Row 2
- Case
- Owned gas boiler
- Established facts
- Boiler is a direct combustion source within the reporting boundary; heat serves the same included operation
- Boundary decision
- Assess gas combustion in Scope 1; do not add the self-produced heat as purchased heat in Scope 2
- Evidence still needed
- Fuel quantity and source record; identify any separately acquired auxiliary electricity
Row 3
- Case
- District cooling
- Established facts
- External supplier generates cooling delivered to an operation inside the reporting boundary
- Boundary decision
- Include the acquired cooling stream in Scope 2
- Evidence still needed
- Supply contract, delivered-energy basis and supplier information for the later calculation
Row 4
- Case
- Purchased CHP steam
- Established facts
- Separate supplier operates the combined heat and power plant; buyer acquires steam consumed inside its boundary
- Boundary decision
- Include the acquired steam stream in Scope 2
- Evidence still needed
- Delivered quantity and support for allocation of generator emissions to the steam output
The leased-office result does not follow from the recharge alone. Under the operational-control approach, the GHG Protocol guidance generally treats tenants as exercising operational control unless the lease demonstrates otherwise; any justified exclusion needs documentation. If the available facts establish only that a landlord sent a bill, leave classification pending while obtaining the consolidation approach and control facts. A payment record cannot substitute for that assessment.
For the CHP case, knowing that steam is included does not make the entire plant's emissions the buyer's steam emissions. The generator produces several energy outputs. Allocation and a suitable supplied-steam basis are later calculation questions. If the plant is actually inside the buyer's reporting boundary, the external-supplier premise fails and the case must be reconsidered as a direct-source arrangement.
The district-cooling case likewise distinguishes inclusion from quantity readiness. A service contract can establish the nature of supply while an invoice still lacks the necessary physical consumption basis. Mark the source included but its quantity pending, rather than either omitting cooling or inventing a conversion from price.
A site-by-site inclusion checklist
Create one register for a defined site and reporting period. Before using the rows below, fill the common header: site [name and operation]; period [start and end]; reporting entity [name]; consolidation approach [equity share, financial control or operational control]; boundary decision owner [name and role]. If the boundary changes during the period, separate the affected intervals so that one status does not conceal two arrangements.
| Energy stream | Source and generator | Consumption evidence | Quantity and unit | Decision and reason | Record and owner |
|---|---|---|---|---|---|
| Electricity | [Supplier, generating arrangement, route through utility, landlord or direct line] | [Meter, tenant allocation or other supported basis] | [Quantity, original unit and period; pending if unknown] | [Included, excluded or pending; boundary rationale] | [Document reference, version and responsible contact] |
| Steam | [Supplier, generator and delivered steam connection] | [Delivery or meter record for the consuming operation] | [Quantity and unit; thermal information or conversion still required] | [Included, excluded, pending or confirmed absent; reason] | [Contract or source reference and responsible contact] |
| Heat | [Supplier, generating arrangement and heat connection] | [Meter or supported delivered-heat record] | [Quantity, energy unit and period; pending if unknown] | [Included, excluded, pending or confirmed absent; reason] | [Source reference, version and responsible contact] |
| Cooling | [Supplier, generating arrangement and cooling connection] | [Delivered-cooling record and served operation] | [Quantity and energy basis; unresolved conversion stated] | [Included, excluded, pending or confirmed absent; reason] | [Source reference, version and responsible contact] |
Table 2, shown one row at a time. Every field is retained.
Row 1
- Energy stream
- Electricity
- Source and generator
- [Supplier, generating arrangement, route through utility, landlord or direct line]
- Consumption evidence
- [Meter, tenant allocation or other supported basis]
- Quantity and unit
- [Quantity, original unit and period; pending if unknown]
- Decision and reason
- [Included, excluded or pending; boundary rationale]
- Record and owner
- [Document reference, version and responsible contact]
Row 2
- Energy stream
- Steam
- Source and generator
- [Supplier, generator and delivered steam connection]
- Consumption evidence
- [Delivery or meter record for the consuming operation]
- Quantity and unit
- [Quantity and unit; thermal information or conversion still required]
- Decision and reason
- [Included, excluded, pending or confirmed absent; reason]
- Record and owner
- [Contract or source reference and responsible contact]
Row 3
- Energy stream
- Heat
- Source and generator
- [Supplier, generating arrangement and heat connection]
- Consumption evidence
- [Meter or supported delivered-heat record]
- Quantity and unit
- [Quantity, energy unit and period; pending if unknown]
- Decision and reason
- [Included, excluded, pending or confirmed absent; reason]
- Record and owner
- [Source reference, version and responsible contact]
Row 4
- Energy stream
- Cooling
- Source and generator
- [Supplier, generating arrangement and cooling connection]
- Consumption evidence
- [Delivered-cooling record and served operation]
- Quantity and unit
- [Quantity and energy basis; unresolved conversion stated]
- Decision and reason
- [Included, excluded, pending or confirmed absent; reason]
- Record and owner
- [Source reference, version and responsible contact]
Use separate fields for boundary status and data completeness. An included source can have a missing meter reading; an excluded source can have excellent quantity data. Combining these into a single complete/incomplete flag makes it harder to direct the next request. For every pending decision, name the missing fact rather than writing “check later”.
Where a stream is confirmed absent, identify who confirmed it and the basis. Where it is excluded, state the destination of further assessment, such as direct combustion or a value-chain activity. Keep quantity and factor work linked to the same source reference so a later calculation cannot quietly use a different site or period.
This is a source register rather than a second emissions total. Do not sum its mixed electricity, steam, heat and cooling quantities without an appropriate common energy basis. Its first completion test is whether all four streams received an explicit, supported decision and each unresolved item has an owner.
Included activity is not the same as the reported factor
Including acquired electricity in the register and selecting its emissions factor are separate steps. A renewable supply contract or energy attribute certificate can affect the evidence used for a market-based calculation, subject to the relevant criteria. It does not erase electricity that the operation acquired and consumed.
Keep the consumption record intact and link the contractual evidence to the appropriate source and period. If the instrument's eligibility is unresolved, that uncertainty belongs in the factor assessment. It is not a reason to delete the source from the activity boundary or enter zero consumption.
Location-based and market-based reporting requirements can then be addressed using the applicable guidance. This checklist does not choose between them, provide a factor hierarchy or calculate a result. It supplies the defined activity population on which that later work depends.
Keep each source connected to its decision
A workable record system connects each source to its site, period, boundary rationale and supporting documents. The useful connection is specific: a lease supports a control decision, a meter supports consumption, and a supply agreement explains an acquired stream. A folder containing all three files without those relationships still leaves the next reporting owner to reconstruct the decision.
Choose a record owner who can maintain those connections when a supplier, lease or generating arrangement changes. Preserve the previous decision and the reason for any revision. Organising evidence supports a repeatable inventory process; it does not by itself validate certificates, provide assurance or establish compliance with a reporting scheme.
Once the boundary is settled, choose the next task
Once all four streams have a supported boundary status, choose the next task from the remaining gap. If an included stream lacks physical consumption evidence, resolve its quantity. If the activity record is ready but generation or contractual evidence is incomplete, investigate the appropriate factor and method. A change in ownership, control or supply arrangement sends the source back to the boundary decision.
Treat a site as ready for calculation when the included activity population is explained, not merely when every visible bill has a number beside it. The register should also explain absent streams and exclusions, so completeness can be tested by someone other than its author.
That gives the reporting team a durable starting point: electricity, steam, heat and cooling have each been considered; direct and value-chain sources have identifiable destinations; and unresolved facts remain visible. The next calculation can then answer how much was emitted from the defined acquired energy, rather than trying to repair the inventory boundary through arithmetic.
Scope 2: purchased energy