A man holding a tablet stands beside utility meters and large metal pipes in a building service area.
The energy equipment provides context; records establish the case.
Diagram text description

A synthetic editorial scene shows a person with a tablet beside meters and metal pipework. No legible activity quantity, ownership contract, customer result or emissions factor is visible.

Scope 2 emissions examples are useful when they reveal the fact that changes the answer. An electricity bill, a steam pipe and solar panels on a roof can all appear at the same factory, but they do not establish the same source, reporting boundary or emissions factor. Start with what the reporting company controls, what energy it acquires and what evidence supports the quantity.

The six cases below are fictional situations for a company using operational control across its inventory: direct-bill office electricity, a tenant allocation, purchased steam, district cooling, rooftop solar and electricity with a certificate. A company-operated gas boiler provides a separate control case. Purchased electricity and thermal services are Scope 2 candidates; controlled combustion is a Scope 1 source. A certificate concerns eligible method evidence rather than whether energy was consumed. Reassess the cases if the consolidation approach or control facts differ.

The accounting distinctions follow the final 2015 Scope 2 Guidance. Proposed revisions are not treated as adopted rules. The example quantities, record identifiers and factors illustrate decisions; they are not customer results or factors for a real inventory. Each case identifies the record to obtain before its conclusion can be used.

Example 1: an office buying grid electricity

Fictional North Quay Components operates an office within its operational-control boundary. Meter O-17 supplies that office, and utility bill UB-25 records 10,000 kWh for the stated 2025 reporting period. The company acquires and consumes electricity generated outside its boundary, so the generation emissions belong in its Scope 2 inventory. The record establishes purchased electricity activity, not the company’s entire footprint. An invented factor is applied later, after the case facts are fixed.

  • Match the bill’s meter and service address to the office register.
  • Reconcile opening and closing dates with the reporting period, including any overlapping bill.
  • Record 10,000 kWh as energy, separately from the monetary charge.
  • Select evidence for the relevant grid region, factor year and generation boundary.
  • Keep location-based and, where applicable, market-based factor evidence in separate fields.

Suppose the December bill is estimated and is replaced in February. Preserve the original activity version and the actual replacement quantity, with the period to which it belongs. A payment date alone does not move December consumption into the following inventory. If the bill combines this office with a neighbouring warehouse, first obtain the meter schedule or a defensible allocation. Multiplying the combined quantity would otherwise give the office credit for somebody else’s electricity.

Example 2: a tenant behind the landlord meter

A tenant can acquire electricity through rent or a service charge without holding a utility account. In the fictional leased office, operational control is established by the lease facts. The landlord’s meter covers the tenant, other occupiers and shared space. The whole-building bill therefore supports the building quantity; it does not by itself establish the reporting company’s share.

Record the lease boundary, meter coverage and allocation method together. If a submeter exists, reconcile its period and unit with the landlord statement. If consumption is estimated, describe the basis, such as occupied area and occupancy periods, and explain how common services are treated. A flat annual rent figure cannot be converted into kWh without another supported method. Label an allocation as an estimate when it is one.

A whole-building meter frame contains the reporting tenant, other occupiers and shared space as separate parts.
Separate the tenant share from other occupiers and common areas.
Diagram text description

The landlord meter records the whole building. A documented allocation separates the reporting tenant from other occupiers and common areas. Confirm which shared services the allocation includes before using the tenant quantity.

For an explicitly fictional allocation, assume a reconciled building total of 50,000 kWh and a documented 20% tenant share for the same period, including that tenant’s assigned common-area use. The tenant record is 10,000 kWh; the remaining 40,000 kWh is not also entered into its inventory. These numbers demonstrate the allocation, not a recommended area ratio for every lease.

The answer changes if the tenant demonstrates that it lacks operational control over the relevant asset under its declared consolidation approach. Document that conclusion and assess the applicable leased-asset treatment instead of automatically assigning every rented space to Scope 2. Ask the property manager for the meter map and allocation schedule before treating an unexplained service charge as complete energy evidence.

Example 3: a factory buying process steam

The fictional factory purchases process steam from an external combined heat and power plant. The supplier burns fuel and produces both electricity and steam. For the customer, the purchased steam is a Scope 2 energy stream within the assumed boundary. The plant’s total fuel emissions cannot simply be assigned to the steam customer because another output also receives a share.

The useful connection is between the steam delivery record and the supplier’s output allocation. A plant-wide emissions total, an electricity factor and a steam-specific generation factor are different evidence objects. The last must explain how the shared combustion emissions have been allocated across outputs.

Shared CHP fuel emissions branch through supplier allocation into electricity and purchased steam.
A shared CHP input needs an output-specific steam allocation.
Diagram text description

The CHP plant uses one fuel input to produce electricity and steam. The supplier allocation assigns emissions to each output. The customer uses the purchased steam quantity and its supported steam-specific generation factor, rather than all plant emissions.

  1. Confirm that the steam is acquired from an external operator, rather than generated by a boiler the reporting company controls.
  2. Preserve the delivered quantity in its original unit, the supply period and the delivery point.
  3. Request the supplier’s CHP allocation method, output quantities and the boundary of the resulting steam factor.
  4. If mass must become thermal energy, obtain the necessary steam and return-condition data rather than assuming tonnes of steam equal a fixed number of gigajoules.
  5. Match the resulting activity unit to a steam generation factor and retain every conversion.

A supplier statement marked “recovered heat” does not itself justify a zero factor. The underlying generation and allocation still need an accounting basis. If the supplier cannot explain the allocation, retain the purchased quantity and flag the factor as unresolved; a grid-electricity factor would not repair the missing steam evidence. The decisive request is for the output-specific method and source data. If control of the generating plant instead belongs to the reporting company, revisit direct combustion and allocation within that boundary before using this purchased-steam conclusion.

Example 4: a warehouse buying district cooling

The warehouse in this fictional case buys chilled water from an external district cooling plant. A delivery meter records cooling received during the reporting period. This is purchased cooling, so its Scope 2 calculation needs a cooling quantity and a factor that represents generation of that cooling. The supplier’s fuel, electricity use, efficiency and allocation may matter to that factor.

Compare that arrangement with a warehouse that operates its own electric chiller. The second warehouse purchases electricity, then converts some of it into cooling inside its boundary. The chiller’s electricity is already part of the relevant site electricity record. Adding another purchased-cooling result for the cooling produced by that chiller would count the same energy twice.

One path buys chilled water from an external plant; another buys electricity for a company chiller.
Identify what crosses the boundary: cooling or electricity.
Diagram text description

For an external cooling plant, retain the delivered cooling record and a matching cooling generation factor. For a company electric chiller, record its electricity within the site electricity total. Do not add a second purchased-cooling result for that same company-produced cooling.

Use the cooling contract and plant-control record to decide which arrangement exists. For district cooling, retain the delivery meter, thermal unit, period and supplier factor method. If the invoice shows only water volume, obtain the evidence needed to determine delivered thermal energy; litres of circulating water alone do not describe the cooling supplied. For the company chiller, reconcile any submeter to the main electricity total rather than adding it again.

A single site can have both arrangements in different areas. Separate those activities by meter and service boundary. Chiller refrigerant leakage is another source to assess under the company’s control; it should not be hidden inside the purchased-electricity quantity. The practical next step is a service and meter map, not a second factor applied to an already counted electricity bill.

Counterexample: the company runs its own gas boiler

The fictional company operates a gas boiler, buys its fuel and controls combustion. Under the operational-control approach used here, the boiler’s direct combustion emissions are Scope 1. The fact that its output heats the office does not turn the fuel into purchased heat. The company is purchasing a fuel input and generating heat itself.

  • Confirm who controls operation and maintenance of the boiler.
  • Match the gas account and fuel quantity to that equipment and reporting period.
  • Keep the direct combustion calculation separate from purchased electricity.
  • Check whether any heat is also bought from a separately controlled external operator.

For example, an invoice from a maintenance contractor may include a service fee while the company retains operational control. That contractor’s name on the invoice does not establish an external heat purchase. Conversely, a contract may show that another operator controls generation and sells measured heat to the company. In that changed case, examine the acquired heat as Scope 2 rather than carrying the original boiler conclusion forward.

Retain the control evidence with the source register, including the contract clause that resolved an uncertain arrangement. Fuel use and purchased heat can coexist at one site, but each needs its own activity record. The control case prevents a broader error: “energy used for heating” describes a purpose, while the source and organisational boundary determine the accounting treatment.

Example 5: solar generation at the company site

Panels on the company roof do not settle the Scope 2 answer. In the first fictional arrangement, the reporting company controls the solar generator, consumes its output and retains the relevant attributes. That is self-generation; the consumed output is not an external electricity purchase merely because it passes through a meter. Solar photovoltaic generation has no fuel-combustion emissions at the point of generation, but this does not make its equipment or wider life cycle emission-free.

In the second arrangement, a third party controls the rooftop generator and sells electricity to the company under a power purchase agreement. The company acquires energy from outside its boundary. Inspect the PPA, generation and consumption meters, and the rights to attributes before determining the applicable method factors. The physical location can be identical while the purchase and control facts differ.

Company generation and third-party sold electricity occupy separate columns above a shared attribute check.
Check generator control, the electricity sale and the attributes separately.
Diagram text description

Company-controlled solar used on site is self-generation, subject to the treatment of any attributes sold or transferred. Electricity purchased from a third-party rooftop generator is acquired energy. In both arrangements, inspect the contract and attribute ownership before making a renewable or zero-emission claim.

Attribute sales create a further condition even for company-controlled generation. If the company transfers away the certificates associated with energy it consumes, it cannot also retain the same renewable attribute claim. The guidance’s treatment uses the applicable factor hierarchies for that consumed energy; do not stop at “we own the panels.” Keep retention, retirement or transfer records beside the generation record.

Also distinguish gross grid imports from exports. An annual net bill can hide electricity purchased at one time and generation sold at another. Preserve imported energy, self-consumed generation and exports as separate quantities. A favourable net balance does not erase gross purchased electricity. Where the meter cannot distinguish those flows, document the limitation and request the missing interval or import/export evidence.

Example 6: an electricity purchase with a renewable certificate

A certificate changes the evidence available for a market-based calculation when it satisfies the applicable criteria. It does not delete the electricity purchase. In a fictional 100 MWh purchase, assume instruments are presented for 40 MWh. The remaining 60 MWh still needs the appropriate factor from the market-based hierarchy. The 40 MWh is only potentially covered until its evidence is checked.

The coverage split describes quantities, not a verified environmental claim. Check what emission-rate attribute the instrument conveys, whether another instrument conveys the same claim, and whether it was retired or cancelled for the reporting entity. Check the relevant consumption period and market. Supplier factors also need their appropriate delivered-electricity basis. A green label or a purchase receipt alone does not complete these tests.

A fictional 100 MWh purchase is split into 40 MWh conditional certificate coverage and 60 MWh uncovered activity.
Fictional purchase: 40 MWh potentially covered, 60 MWh still uncovered.
Diagram text description

The fictional purchase remains 100 MWh. Only 40 MWh could use the instrument-derived factor if the evidence meets the applicable quality criteria. The other 60 MWh needs the appropriate hierarchy factor. If the instrument fails, the affected 40 MWh also needs other eligible factor evidence.

Under the final guidance, companies with operations in markets providing the relevant contractual information report both location-based and market-based Scope 2 results. These are two accounts of the same purchased activity using different factor evidence; do not add their totals. Lack of a certificate purchase does not automatically remove the market-based reporting obligation.

For the uncovered portion, follow the applicable hierarchy: other eligible contractual or supplier data may be relevant, followed by an appropriate residual mix. Grid-average data can be a fallback when the preceding data are unavailable, with the required disclosure. Do not automatically assign zero or assume the location-based factor is the first market-based choice.

If the 40 MWh instrument fails a criterion, those 40 MWh also need other eligible factor evidence. The activity record remains 100 MWh in either outcome. A small worked example below illustrates the arithmetic without presenting any real certificate as checked, and without suggesting that an attributed result proves the physical electricity at the socket had no emissions.

Compare the scenarios by evidence and failure mode

The comparison uses the same operational-control assumption as the cases above. Each row pairs a classification with the evidence that could change it. The six examples are separate situations, not six quantities to add into one company total. The gas boiler row is a counterexample that tests whether heat was generated inside or acquired across the boundary.

Case and purchased or controlled activityScope treatment under the stated factsDecisive record and condition that changes the answer
Direct-bill office: electricity from the utility gridScope 2 generation emissions for acquired electricityMeter, period-matched kWh bill and factor basis. Shared meter coverage requires allocation first.
Tenant: electricity acquired through the landlordScope 2 for the controlled leased operationLease, meter map and tenant allocation. Demonstrated lack of operational control requires a different leased-asset assessment.
Factory: steam from an external CHP operatorScope 2 purchased steam, using its output-specific generation basisSteam delivery and supplier CHP allocation. Company control of generation changes the direct-source assessment.
Warehouse: chilled water bought from an external plantScope 2 purchased coolingCooling contract, delivery quantity and supplier method. A company-operated electric chiller uses site electricity already recorded.
Rooftop solar: own generation or third-party electricity saleSelf-generation under retained attributes differs from externally acquired electricityControl record, PPA, generation flows and attribute transfers. Selling attributes changes the self-consumption treatment and claims.
Certificate electricity: the full purchase remains activityLocation-based result and, where applicable, a separate market-based resultConsumption and eligible instrument evidence. Failed eligibility requires other hierarchy data for the affected quantity.
Control case: company-operated gas boilerScope 1 direct combustionFuel and operational-control records. Externally generated purchased heat is a different Scope 2 test.

Table 1, shown one row at a time. Every field is retained.

Row 1

Case and purchased or controlled activity
Direct-bill office: electricity from the utility grid
Scope treatment under the stated facts
Scope 2 generation emissions for acquired electricity
Decisive record and condition that changes the answer
Meter, period-matched kWh bill and factor basis. Shared meter coverage requires allocation first.

Row 2

Case and purchased or controlled activity
Tenant: electricity acquired through the landlord
Scope treatment under the stated facts
Scope 2 for the controlled leased operation
Decisive record and condition that changes the answer
Lease, meter map and tenant allocation. Demonstrated lack of operational control requires a different leased-asset assessment.

Row 3

Case and purchased or controlled activity
Factory: steam from an external CHP operator
Scope treatment under the stated facts
Scope 2 purchased steam, using its output-specific generation basis
Decisive record and condition that changes the answer
Steam delivery and supplier CHP allocation. Company control of generation changes the direct-source assessment.

Row 4

Case and purchased or controlled activity
Warehouse: chilled water bought from an external plant
Scope treatment under the stated facts
Scope 2 purchased cooling
Decisive record and condition that changes the answer
Cooling contract, delivery quantity and supplier method. A company-operated electric chiller uses site electricity already recorded.

Row 5

Case and purchased or controlled activity
Rooftop solar: own generation or third-party electricity sale
Scope treatment under the stated facts
Self-generation under retained attributes differs from externally acquired electricity
Decisive record and condition that changes the answer
Control record, PPA, generation flows and attribute transfers. Selling attributes changes the self-consumption treatment and claims.

Row 6

Case and purchased or controlled activity
Certificate electricity: the full purchase remains activity
Scope treatment under the stated facts
Location-based result and, where applicable, a separate market-based result
Decisive record and condition that changes the answer
Consumption and eligible instrument evidence. Failed eligibility requires other hierarchy data for the affected quantity.

Row 7

Case and purchased or controlled activity
Control case: company-operated gas boiler
Scope treatment under the stated facts
Scope 1 direct combustion
Decisive record and condition that changes the answer
Fuel and operational-control records. Externally generated purchased heat is a different Scope 2 test.

An open case needs a targeted request. The property manager holds the tenant allocation; the operator contract resolves boiler control; the CHP supplier explains the steam allocation; the cooling contract identifies the delivered service; and the solar PPA and attribute records establish the electricity sale and claim rights. Ask the person holding that evidence to resolve the named condition. A bill description or a photograph cannot substitute for it. Until then, retain the activity and uncertainty explicitly rather than selecting the most convenient scope or lowest factor.

One fictional calculation, with its limits plainly labelled

Fictional calculation: North Quay Components’ office has 10,000 kWh of purchased electricity for its 2025 inventory under operational control. This example covers electricity generation only. All factors below are invented teaching values, not published rates for a place or year. Assume the location-based factor already expresses CO₂e and the separate market-based illustration has complete eligible evidence for its stated portions.

Fictional calculation or controlCompatible inputs and operationResult and decision
Location-based office electricity10,000 kWh × invented 0.40 kg CO₂e/kWh = 4,000 kg CO₂e; divide by 1,000 kg per tonne4.0 t CO₂e, location-based generation result.
Conditional market-based covered share4,000 kWh × invented eligible-instrument rate 0.05 kg CO₂e/kWh200 kg CO₂e, only under the stated fictional eligibility assumption.
Conditional market-based remainder6,000 kWh × invented appropriate residual-mix rate 0.50 kg CO₂e/kWh3,000 kg CO₂e for the remaining activity.
Separate market-based total200 + 3,000 = 3,200 kg CO₂e; divide by 1,0003.2 t CO₂e, market-based. Report beside 4.0 t; do not add the methods.
Inapplicable factor control10,000 kWh electricity and a gas-combustion factor stated per kWh of fuelWithhold the result. Matching unit symbols do not make the gas factor applicable to electricity generation.
Missing factor control10,000 kWh electricity; no supported grid factor or applicable market hierarchy factorResult unresolved, not zero. Obtain the missing factor evidence and document the gap.

Table 2, shown one row at a time. Every field is retained.

Row 1

Fictional calculation or control
Location-based office electricity
Compatible inputs and operation
10,000 kWh × invented 0.40 kg CO₂e/kWh = 4,000 kg CO₂e; divide by 1,000 kg per tonne
Result and decision
4.0 t CO₂e, location-based generation result.

Row 2

Fictional calculation or control
Conditional market-based covered share
Compatible inputs and operation
4,000 kWh × invented eligible-instrument rate 0.05 kg CO₂e/kWh
Result and decision
200 kg CO₂e, only under the stated fictional eligibility assumption.

Row 3

Fictional calculation or control
Conditional market-based remainder
Compatible inputs and operation
6,000 kWh × invented appropriate residual-mix rate 0.50 kg CO₂e/kWh
Result and decision
3,000 kg CO₂e for the remaining activity.

Row 4

Fictional calculation or control
Separate market-based total
Compatible inputs and operation
200 + 3,000 = 3,200 kg CO₂e; divide by 1,000
Result and decision
3.2 t CO₂e, market-based. Report beside 4.0 t; do not add the methods.

Row 5

Fictional calculation or control
Inapplicable factor control
Compatible inputs and operation
10,000 kWh electricity and a gas-combustion factor stated per kWh of fuel
Result and decision
Withhold the result. Matching unit symbols do not make the gas factor applicable to electricity generation.

Row 6

Fictional calculation or control
Missing factor control
Compatible inputs and operation
10,000 kWh electricity; no supported grid factor or applicable market hierarchy factor
Result and decision
Result unresolved, not zero. Obtain the missing factor evidence and document the gap.

The location-based multiplication cancels kWh, leaving kilograms of CO₂e. Dividing by 1,000 converts that mass to tonnes exactly once. The market-based portions also sum to 10,000 kWh, so no consumption disappears between methods. This is a 10 MWh calculation, distinct from the earlier 100 MWh coverage illustration; the 40% split is reused only to make the teaching example easy to follow.

Keep a record of the input version, factor identifier, unit, boundary and calculation expression. A real location-based factor must match the relevant grid and time basis; a real market-based rate needs its own qualifying evidence. If instrument eligibility is unresolved, the conditional 3.2 t illustration cannot be promoted into an approved inventory result. Obtain other eligible hierarchy data for the affected quantity. Neither a missing rate nor a factor for another energy stream can be repaired by treating the result as zero.

Why two similar sites may report different values

Two warehouses can have similar floor areas and still report different Scope 2 values. Floor area is neither the purchased-energy quantity nor the emissions factor. Start by comparing actual activity: operating hours, refrigeration demand, equipment loads and occupancy can produce different electricity use even when the buildings look alike.

Then examine independent causes. A different grid region or factor year can change the location-based result. A supplier’s CHP allocation can change a purchased-steam rate. Adding a newly controlled building changes the included source set. Eligible contractual evidence can change a market-based result without changing metered electricity. Keep those changes separate when explaining a difference; an attributed procurement change is not automatically evidence of lower physical demand.

For a useful comparison, reconcile energy units, reporting periods and gross purchases first. Confirm the same consolidation approach and list any boundary change. Compare factor versions and generation boundaries, then show contractual coverage and the method used. A lower total becomes interpretable only after those checks. If one site reports a location-based figure and the other a market-based figure, first obtain comparable method results.

Use a bridge in the supporting record: identify the changed input, its evidence and which result it affects. Avoid calling every fall an efficiency improvement. Meter evidence can support lower demand; factor and contract evidence explain other movements. This gives the facilities team a specific operational question while keeping procurement and accounting changes visible.

Keep a source record for each site case

A practical site-case register keeps the evidence close to the decision it supports. Give each energy stream a stable record and identify who can resolve the open condition. Use one row per site, period and energy stream so that source changes and unresolved conditions stay attached to the right activity.

FieldFilled fictional site-case record
Site, period and boundaryNorth Quay office O-17, 2025, operational control
Purchased activity10,000 kWh, utility bill UB-25, electricity generation boundary
Source and method referencesMeter O-17, bill version 1; location-based factor field awaiting a real region/year source
Contractual evidenceInstrument claim under review; retirement and market evidence not yet supplied
Accountable next actionProcurement owner requests the instrument evidence; inventory owner selects supported factors
Decision statusActivity retained; real emissions result and instrument claim remain unresolved

Table 3, shown one row at a time. Every field is retained.

Row 1

Field
Site, period and boundary
Filled fictional site-case record
North Quay office O-17, 2025, operational control

Row 2

Field
Purchased activity
Filled fictional site-case record
10,000 kWh, utility bill UB-25, electricity generation boundary

Row 3

Field
Source and method references
Filled fictional site-case record
Meter O-17, bill version 1; location-based factor field awaiting a real region/year source

Row 4

Field
Contractual evidence
Filled fictional site-case record
Instrument claim under review; retirement and market evidence not yet supplied

Row 5

Field
Accountable next action
Filled fictional site-case record
Procurement owner requests the instrument evidence; inventory owner selects supported factors

Row 6

Field
Decision status
Filled fictional site-case record
Activity retained; real emissions result and instrument claim remain unresolved

The register distinguishes a complete activity record from an approved calculation. A bill revision should identify the earlier version it replaces, while a factor change should retain its own reason and effective period. Keep the reviewer’s question with the relevant case rather than in an unconnected email. When the missing evidence arrives, record the resolved condition and the resulting decision so the next preparer can follow it.

Use examples to decide the next practical step

Use these examples to identify the decision your own evidence must support. First decide whether the company controls generation or acquires energy from another entity. Next establish its consumed quantity, including any tenant allocation or gross import record. Only then select a factor and, where relevant, inspect contractual evidence for a separate market-based result.

A difficult lease or ownership arrangement belongs in a detailed inclusion assessment. A missing steam or cooling method belongs in a supplier evidence request. An electricity calculation with a supported boundary can move to the calculation workflow for all relevant purchased-energy streams. Those are different next steps, so name the unresolved condition before asking for a final total.

The fictional numbers demonstrate allocation, compatible units and separate methods. They are not substitutes for actual meter records, regional factors or eligible instruments. Preserve the source versions and assign the next action to the person able to obtain the decisive evidence. A useful case ends with a reproducible decision or a clearly stated open question; both are more informative than a confident number built on an unexplained assumption.